钛制输液港导管接触性过敏:诊断挑战与临床解决

Contact allergy to a titanium port catheter: Diagnostic challenges and clinical resolution.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

钛及其合金因其良好的生物相容性和机械性能而广泛应用于现代医疗器械。对钛基植入物的过敏反应被认为较为罕见,且由于金属过敏原的皮肤渗透性较差,其诊断受到阻碍。一名29岁女性患者,患有血清阴性重症肌无力,需要肠外营养,于2023年7月植入钛制输液港导管(X-Port BARD Titan低 Profile型)后4周,在导管覆盖区域出现持续性炎症性皮炎。尽管最初诊断不明确并进行了序贯性治疗调整,她的病情仍持续恶化。在对侧胸部重新植入相同型号的钛制输液港后,出现了类似的皮疹。采用标准化胶带剥离法和延长判读间隔的严格斑贴试验显示,患者对钛制输液港主体呈阳性致敏反应,而所有其他输液港组件及替代性塑料输液港系统(BARD SlimPort M.R.I. 超低Profile型)均为阴性。能量色散X射线光谱证实钛主体成分为Ti-Al6-V4合金。于2025年2月更换为塑料输液港导管后,症状完全缓解,至2025年7月持续保持临床缓解。尽管非常罕见,但对钛医疗器械的接触性致敏仍可能发生,并可能带来显著的诊断和治疗挑战。严格的斑贴试验方法,包括标准化胶带剥离和延长至168小时的判读,对于检测对金属植入物的迟发型超敏反应似乎至关重要。生物相容性器械替换后临床缓解支持本例的过敏病因学。

Abstract

Titanium and its alloys are widely used in modern medical devices because of their favorable biocompatibility and mechanical properties. Allergic reactions to titanium-based implants are considered rare, and their diagnosis is hampered by the poor dermal penetration of metallic allergens. A 29-year-old female patient with seronegative myasthenia gravis requiring parenteral nutrition presented with persistent inflammatory dermatitis overlying a titanium port catheter (X-Port BARD Titan low-profile) 4 weeks after implantation in July 2023. Despite initial diagnostic uncertainty and sequential management modifications, her condition continued to deteriorate. Similar eruptions developed after re-implantation of the same titanium port model on the contralateral thorax. Rigorous patch testing incorporating standardized tape-stripping and extended reading intervals revealed positive sensitization to the titanium port body, while all other port components and an alternative plastic port system (BARD SlimPort M.R.I. Ultra Low-Profile) tested negative. Energy-dispersive X-ray spectroscopy confirmed the titanium body composition as a Ti-Al6-V4 alloy. Substitution with the plastic port catheter in February 2025 resulted in complete symptom resolution, with sustained clinical remission through July 2025. Although very uncommon, contact sensitization to titanium medical devices can occur and may present significant diagnostic and therapeutic challenges. Rigorous patch testing methodology, incorporating standardized tape-stripping and extended 168-hour readings, appears essential for detecting delayed-type hypersensitivity to metallic implants. Clinical resolution following biocompatible device substitution supports an allergic etiology in this case.

如何引用

AMA

Silas Fugger, Alexander Kauffmann, Heinrich Dickel. Contact allergy to a titanium port catheter: Diagnostic challenges and clinical resolution.. Allergologie select. 2026; doi:10.5414/ALX02637E.

APA

Silas Fugger, Alexander Kauffmann, Heinrich Dickel (2026). Contact allergy to a titanium port catheter: Diagnostic challenges and clinical resolution.. Allergologie select. https://doi.org/10.5414/ALX02637E

GB/T 7714

Silas Fugger, Alexander Kauffmann, Heinrich Dickel. Contact allergy to a titanium port catheter: Diagnostic challenges and clinical resolution.[J]. Allergologie select, 2026 doi:10.5414/ALX02637E.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Allergologie select 的其他文献