缝合钉技术与对照侧对侧内镜臀中肌修复术的等效患者报告结果

Equivalent Patient-Reported Outcomes for Suture Staple Technique Versus Control Side-To-Side Endoscopic Gluteus Medius Repair.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

比较在至少24个月随访时,采用缝合钉技术进行内镜下臀中肌修复与对照的侧侧修复的结果。开展了一项回顾性、单中心研究,时间范围为2015年1月至2021年12月,数据收集于一个过渡时期,在此期间不断演变的手术实践促使采用缝合钉技术。纳入所有随访至少2年且接受至少6个月结构化非手术治疗的患者。采用改良Harris髋关节评分、维多利亚运动评估研究所-臀肌评分和视觉模拟量表评估结果。统计分析包括Student t检验和Wilcoxon检验以比较组间差异,显著性设定为P < .05。共分析61例患者(对照组n = 31;缝合钉组n = 30)。总体平均年龄为65.7岁(标准差[SD] = 10.4岁);对照组为65.2岁(SD = 10.7岁),缝合钉组为66.1岁(SD 10.3岁)。队列以女性为主(78.7%),其中对照组女性占80.6%,缝合钉组女性占76.7%。平均随访时间为72.7个月(SD 34.4;范围24-142)。对照侧侧组的随访时间显著长于缝合钉组(平均82.8个月,SD 31.6 vs 62.3个月,SD 34.6;P = .0180)。改良Harris髋关节评分从术前32.7(SD 19.1)提高至术后71.0(SD 18.2),组间无显著差异(P = .5322)。维多利亚运动评估研究所-臀肌评分改善40.2个单位(SD 22.6),85.2%达到11.3的最小临床重要差异(P = .4635)。视觉模拟量表评分从7.7(SD 2.1)降至2.7(SD 2.0),90.2%达到1.3的最小临床重要差异,无显著差异(P = .1058)。按性别分层的分析显示,男性和女性在改良Harris髋关节评分、维多利亚运动评估研究所-臀肌评分或视觉模拟量表方面,两种技术之间均无显著差异(男性:P分别为.9318、.4400和.4276;女性:P分别为.4288、.7501和.2101)。两种技术提供了相当的功能和疼痛缓解结果。缝合钉技术和侧侧技术对内镜下臀中肌腱修复均有效,在平均6年随访中实现了显著的功能和疼痛评分改善。证据等级III,回顾性比较队列研究。

Abstract

To compare outcomes of endoscopic gluteus medius repair using the suture staple technique versus a control side-to-side repair at ≥24-month follow-up. A retrospective, single-center study from January 2015 to December 2021 was conducted with data collected during a transitional period where evolving surgical practices led to the adoption of the suture staple technique. Included were all patients with ≥2 years of follow-up and ≥6 months of well-structured nonoperative treatment. Outcomes were assessed using the modified Harris Hip Score, Victorian Institute of Sport Assessment - Gluteal, and visual analog scale. Statistical analyses included Student's t-test and Wilcoxon test for comparing group differences, with significance set at P < .05. Sixty-one patients were analyzed (control n = 31; suture staple n = 30). The overall mean age was 65.7 (standard deviation [SD] = 10.4 years); control (65.2 SD = 10.7 years), and suture stable group (66.1, SD 10.3 years). The cohort was predominantly female (78.7%), including 80.6% women in the control group and 76.7% in the suture stable group. Follow-up averaged 72.7 months (SD 34.4; range 24-142). Follow-up was significantly longer in the control side-to-side group than in the suture staple group (mean 82.8 SD 31.6 vs 62.3 SD 34.6 months; P = .0180). The modified Harris Hip Score increased from 32.7 (SD 19.1) preoperatively to 71.0 (SD 18.2) postoperatively, with no significant difference between groups (P = .5322). Victorian Institute of Sport Assessment - Gluteal improved by 40.2 units (SD 22.6), with 85.2% achieving the minimal clinically important difference of 11.3 (P = .4635). Visual analog scale scores decreased from 7.7 (SD 2.1) to 2.7 (SD 2.0), with 90.2% achieving the minimal clinically important difference of 1.3 with no significant difference (P = .1058). Sex-disaggregated analyses revealed no significant between-technique differences in men or women for modified Harris Hip Score, Victorian Institute of Sport Assessment - Gluteal, or visual analog scale (men: P = .9318, .4400, and .4276; women: P = .4288, .7501, and .2101, respectively). Both techniques provided comparable functional and pain relief outcomes. The suture staple technique and side-to-side technique are effective for endoscopic gluteus medius tendon repair, achieving significant functional and pain score improvements over a mean follow-up of 6 years. Level III, retrospective comparative cohort.

如何引用

AMA

Vasileios Giovanoulis, Christos Koutserimpas, Fabricio Luciano Vassallo, Nikolaos Lepidas, Derrick Guo, Mathieu Thaunat. Equivalent Patient-Reported Outcomes for Suture Staple Technique Versus Control Side-To-Side Endoscopic Gluteus Medius Repair.. Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association. 2026; doi:10.1002/arj.70434.

APA

Vasileios Giovanoulis, Christos Koutserimpas, Fabricio Luciano Vassallo, Nikolaos Lepidas, Derrick Guo, Mathieu Thaunat (2026). Equivalent Patient-Reported Outcomes for Suture Staple Technique Versus Control Side-To-Side Endoscopic Gluteus Medius Repair.. Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association. https://doi.org/10.1002/arj.70434

GB/T 7714

Vasileios Giovanoulis, Christos Koutserimpas, Fabricio Luciano Vassallo, Nikolaos Lepidas, Derrick Guo, Mathieu Thaunat. Equivalent Patient-Reported Outcomes for Suture Staple Technique Versus Control Side-To-Side Endoscopic Gluteus Medius Repair.[J]. Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association, 2026 doi:10.1002/arj.70434.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association 的其他文献