手术护理的温室气体排放:一项跨专业和手术方法的范围1和范围2排放的回顾性队列研究
Greenhouse gas emissions from surgical care: a retrospective cohort study of scope 1 and scope 2 emissions across specialties and operative approaches.
Greenhouse gas emissions from surgical care: a retrospective cohort study of scope 1 and scope 2 emissions across specialties and operative approaches.
量化与外科诊疗相关的范围一和范围二温室气体(GHG)排放,并识别机构层面可干预的关键驱动因素,包括手术时长和手术室(OR)类型。回顾性队列研究。日本一家拥有17间手术室的三级大学医院。2022年1月1日至12月31日期间在全身麻醉下实施的全部6996例择期手术。主要结局为每例手术的范围一和范围二二氧化碳当量(CO₂e)总排放量。次要分析评估了不同专科、手术方式(开放、内镜和机器人)以及时间性电力消耗模式之间的排放差异。采用多变量线性回归评估每例手术范围二排放量、手术时长与手术室类型之间的关联。总排放量为1943.4吨CO₂e,其中范围一占71.0%,主要由地氟烷驱动(占总排放量的69.2%)。尽管范围二占机构总排放量的29.0%,但由于挥发性麻醉药的使用,范围一排放主导了大多数单例手术的碳足迹。工作日日间电力消耗仅占每周总用电量的47.7%,超过一半发生在夜间和周末时段,主要归因于供暖、通风和空调(HVAC)的持续运行。回归分析表明,手术时长对每例手术范围二排放量的独立影响有限,而手术室类型——包括复合手术室和生物洁净手术室——与更高的排放量密切相关。麻醉药选择和基础设施相关能源需求是外科温室气体排放的主要决定因素。在直接排放和能源相关排放范围内,减少挥发性麻醉药使用和优化手术室能源消耗——尤其是在非手术时段——是减排最有效的策略。
To quantify Scope 1 and Scope 2 greenhouse gas (GHG) emissions associated with surgical care and identify key modifiable drivers at the institutional level, including operative duration and operating room (OR) type. Retrospective cohort study. A tertiary university hospital with 17 ORs in Japan. All 6996 elective surgeries were performed under general anaesthesia between 1 January and 31 December 2022. The primary outcome was per-case total Scope 1 and Scope 2 carbon dioxide equivalent emissions (COe) emissions. Secondary analyses evaluated emission differences across specialties, surgical approaches (open, endoscopic, and robotic), and temporal electricity consumption patterns. Multivariable linear regression was performed to assess the associations between per-case scope 2 emissions, operative time, and OR type. Total emissions were 1943.4 t COe, of which Scope 1 accounted for 71.0%, predominantly driven by desflurane (69.2% of total emissions). Although scope 2 accounted for 29.0% of total institutional emissions, scope 1 emissions dominated the carbon footprint of most individual procedures because of volatile anaesthetic use. Weekday daytime electricity consumption accounted for only 47.7% of total weekly use, with more than half occurring during nighttime and weekend periods, largely due to continuous heating, ventilation and air conditioning (HVAC) operation. Regression analysis demonstrated that operative time had a limited independent effect on per-case scope 2 emissions, whereas OR type-including hybrid and bio-clean rooms-was strongly associated with higher emissions. Anaesthetic choice and infrastructure-related energy demand are the principal determinants of surgical GHG emissions. Within direct and energy-related emissions, reducing volatile anaesthetic use and optimising OR energy consumption-particularly during non-operative periods-represent the most effective strategies for emission reduction.
Yoshimasa Akashi, Kumiko Yamada, Koichi Ogawa, Yohei Owada, Tsuyoshi Enomoto, Kinji Furuya, et al. Greenhouse gas emissions from surgical care: a retrospective cohort study of scope 1 and scope 2 emissions across specialties and operative approaches.. BMJ open. 2026; doi:10.1136/bmjopen-2026-118294.
Yoshimasa Akashi, Kumiko Yamada, Koichi Ogawa, Yohei Owada, Tsuyoshi Enomoto, Kinji Furuya, et al (2026). Greenhouse gas emissions from surgical care: a retrospective cohort study of scope 1 and scope 2 emissions across specialties and operative approaches.. BMJ open. https://doi.org/10.1136/bmjopen-2026-118294
Yoshimasa Akashi, Kumiko Yamada, Koichi Ogawa, Yohei Owada, Tsuyoshi Enomoto, Kinji Furuya, et al. Greenhouse gas emissions from surgical care: a retrospective cohort study of scope 1 and scope 2 emissions across specialties and operative approaches.[J]. BMJ open, 2026 doi:10.1136/bmjopen-2026-118294.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出