基于基准标记的增强现实在耳廓重建中的精度

Accuracy of fiducial-based augmented reality in auricular reconstruction.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

自体肋软骨重建仍然是全耳或部分耳再造的金标准手术治疗方法。不同的耳亚单位由肋软骨雕刻并组装而成。组装需要特定的技能和训练,包括对耳部解剖的三维(3D)充分理解。在半面短小症患者中,由于面部不对称,耳支架的正确位置放置可能尤为困难。我们开发了一种数字化工作流程,可通过术中增强现实(AR)帮助外科医生正确放置支架,且无需使用术前CT扫描。该数字化工作流程在2023年接受手术的两名患者中进行了示例说明。所有患者均因小耳畸形接受了全耳再造。使用独特的扫描方案从对侧耳获取高分辨率数字印模。为此使用了Trios 3 Wireless口内扫描仪(3Shape A/S,丹麦)。STL文件中的剩余间隙被封闭,并使用Meshmixer(Autodesk,美国)对表面进行平滑处理。将数字耳进行镜像处理,并与患者面部的STL模型(Vectra®,Canfield,美国)一起导入Mimics Innovation Suite(Materialise,比利时)。对数字耳进行正确放置,并打印包含AR基准标记的手术导板,以供术中使用Magic Leap 2(佛罗里达,美国)进行操作。该数字化工作流程使用三个仿真颅骨进行了验证。所有测量的准确性均在自体耳再造所需误差范围内。AR在自体耳廓再造中的应用经验证,似乎可行、精确且有用。具有复杂面部不对称的挑战性病例,如半面短小症,将尤其受益于这一新进展。

Abstract

Reconstruction with autologous costal cartilage remains the gold standard surgical treatment for total or partial ear reconstruction. The different auricular subunits are sculpted from costal cartilage and assembled. The assembly requires a particular skillset and training, including a thorough three-dimensional (3D) understanding of auricular anatomy. The correct positioning of the ear framework can be particularly difficult in patients with hemifacial microsomia because of facial asymmetry. We developed a digital workflow that can help the surgeon in the correct positioning of the framework via per-operative Augmented Reality (AR) and without the use of a pre-operative CT scan. The digital workflow is illustrated for two patients who underwent surgery in 2023. All patients underwent total ear reconstruction for microtia. A high-resolution digital impression was obtained from the contralateral ear using a unique scanning protocol. A Trios 3 Wireless intraoral scanner (3Shape A/S, Denmark) was used for this purpose. The remaining gaps in the STL file were closed, and the surfaces were smoothed using Meshmixer (Autodesk,US). The digital ear was mirrored and imported together with the STL model of the patients face (Vectra®, Canfield, US) in Mimics Innovation Suite (Materialise, Belgium). The digital ear was correctly positioned, and a surgical guide, including AR fiducials, was printed for peroperative use with a Magic Leap 2 (Florida, US). The digital workflow was validated using three dummy skulls. The accuracy for all measurements was within the limits of the requested margin of error for autologous ear reconstruction. The use of AR in Autologous Auricular Reconstruction was validated and appears to be feasible, precise, and useful. Challenging cases with complex facial asymmetry, such as hemifacial microsomia, will particularly benefit from this new development.

如何引用

AMA

Herman Vercruysse, Wouter DE Vos, Pasquier Corthouts, Nasser Nadjmi, Martijn Orye, Elke VAN De Casteele. Accuracy of fiducial-based augmented reality in auricular reconstruction.. Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery. 2026; doi:10.1016/j.jcms.2026.104651.

APA

Herman Vercruysse, Wouter DE Vos, Pasquier Corthouts, Nasser Nadjmi, Martijn Orye, Elke VAN De Casteele (2026). Accuracy of fiducial-based augmented reality in auricular reconstruction.. Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery. https://doi.org/10.1016/j.jcms.2026.104651

GB/T 7714

Herman Vercruysse, Wouter DE Vos, Pasquier Corthouts, Nasser Nadjmi, Martijn Orye, Elke VAN De Casteele. Accuracy of fiducial-based augmented reality in auricular reconstruction.[J]. Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery, 2026 doi:10.1016/j.jcms.2026.104651.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery 的其他文献