热暴露下体力活动期间核心体温的数据驱动估计:系统综述与标准化评估
Data-driven estimation of core body temperature during physical activity under heat exposure: A systematic review and standardized evaluation.
Data-driven estimation of core body temperature during physical activity under heat exposure: A systematic review and standardized evaluation.
在体力活动期间准确、实时地估算核心体温(CBT)对于监测热应激以及降低热环境下热相关疾病风险至关重要。尽管已提出众多使用可穿戴传感器的数据驱动算法,但由于方法学异质性较大且缺乏标准化评估,其实际可靠性仍不明确。本研究将系统综述与标准化定量基准相结合。共纳入38项采用无创输入进行CBT估算的研究。其中,14个符合条件的模型(包括基于卡尔曼滤波的方法、统计模型和机器学习方法)在相同的预处理和评估设置下,使用两个独立数据集重新实现并评估:数据集1(跑步机步行)和数据集2(骑行)。该基准揭示了原始报告性能与标准化条件下复现性能之间的显著差异。对于广泛使用的基于心率的扩展卡尔曼滤波,均方根误差(RMSE)从通常报告的0.21-0.41°C增至数据集1上的0.41°C和数据集2上的0.66°C。纳入皮肤温度在某些配置下改善了追踪精度,但性能提升高度依赖于测量部位和数据集。检测CBT升高(>38.0°C)的灵敏度在各方法间差异显著,尤其是在骑行方案中。总之,没有任何单一CBT估算方法在所有设置下始终优于其他方法。仅基于心率的模型在有限传感条件下提供了稳定的基线,而多模态方法在更受控的场景中提供了有条件的益处。本研究建立了一个标准化基准框架,以支持(可穿戴)CBT估算技术的公平比较、方法选择和未来发展。
Accurate, real-time estimation of core body temperature (CBT) during physical activity is essential for monitoring heat strain and mitigating the risk of heat-related illness under hot environmental conditions. Although numerous data-driven algorithms using wearable sensors have been proposed, their practical reliability remains unclear due to substantial methodological heterogeneity and the absence of standardized evaluation. This study combined a systematic review with a standardized quantitative benchmark. A total of 38 studies employing non-invasive inputs for CBT estimation were identified. Of these, 14 eligible models, including Kalman filter-based methods, statistical models, and machine-learning approaches, were re-implemented and evaluated under identical preprocessing and evaluation settings using two independent datasets: Dataset 1 (treadmill walking, ) and Dataset 2 (cycling, ). The benchmark revealed notable differences between originally reported performance and reproduced performance under standardized conditions. For the widely used heart-rate-based extended Kalman filter, the root mean square error (RMSE) increased from typically reported values of 0.21-0.41 C to 0.41 C on Dataset 1 and 0.66 C on Dataset 2. Incorporating skin temperature improved tracking accuracy in some configurations, but performance gains were highly dependent on measurement site and dataset. Sensitivity for detecting elevated CBT ( 38.0 C) varied markedly across methods, particularly for the cycling protocol. In conclusion, no single CBT estimation approach consistently outperformed others across all settings. Heart-rate-only models provided a stable baseline under limited sensing conditions, whereas multimodal approaches offered conditional benefits in more controlled scenarios. This work establishes a standardized benchmark framework to support fair comparison, method selection, and future development of (wearable) CBT estimation technologies.
Yuanzhe Zhao, Weihao Li, Jeroen Hm Bergmann. Data-driven estimation of core body temperature during physical activity under heat exposure: A systematic review and standardized evaluation.. Building and environment. 2026; doi:10.1016/j.buildenv.2026.114591.
Yuanzhe Zhao, Weihao Li, Jeroen Hm Bergmann (2026). Data-driven estimation of core body temperature during physical activity under heat exposure: A systematic review and standardized evaluation.. Building and environment. https://doi.org/10.1016/j.buildenv.2026.114591
Yuanzhe Zhao, Weihao Li, Jeroen Hm Bergmann. Data-driven estimation of core body temperature during physical activity under heat exposure: A systematic review and standardized evaluation.[J]. Building and environment, 2026 doi:10.1016/j.buildenv.2026.114591.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出