智能手机支持的护理点生物传感平台,具有自校准功能,可快速检测全血中的多种AMI生物标志物
Smartphone-Enabled Point-of-Care Biosensing Platform With Self-Calibration for Rapid Matrix-Resistant Detection of Multiple AMI Biomarkers in Whole Blood.
Smartphone-Enabled Point-of-Care Biosensing Platform With Self-Calibration for Rapid Matrix-Resistant Detection of Multiple AMI Biomarkers in Whole Blood.
急性心肌梗死(AMI)需要超越传统方法的快速诊断,而传统方法受到生物学干扰和复杂性影响,限制了即时检验(POC)应用。为解决这些问题,我们设计了一种蒽醌(AQ)校准的传感单元,结合基于智能手机的分析,用于未经处理全血中AMI生物标志物的通用检测。我们的新型双通道生物传感平台整合AQ作为内在参考标准,建立自校正机制以有效抵消血液基质影响。该平台可在5分钟内实现pg/mL水平的快速定量,无需样本预处理,对cTnI、Mb和CK-MB的检测限分别为0.3、19.7和0.7 pg/mL。基于智能手机的智能分析仪可自动进行实时信号处理,创建闭环POC诊断装置,有望用于未来居家AMI风险监测。这一技术突破显示出对生物基质干扰的显著耐受性,同时保持与临床标准相当的分析灵敏度,代表着向去中心化心血管急诊管理迈出的重要一步。
Acute myocardial infarction (AMI) requires rapid diagnosis beyond conventional methods, which suffer from biological interference and complexity, limiting point-of-care (POC) application. To tackle these issues, we have devised an anthraquinone (AQ)-calibrated sensor unit coupled with smartphone-based analysis for universal detection of AMI biomarkers in untreated whole blood. Our novel dual-channel biosensing platform integrates AQ as an intrinsic reference standard, establishing a self-correction mechanism to effectively counteract hematological matrix influences. The platform enables swift quantification at pg/mL levels within 5 min without sample preprocessing, achieving detection limits of 0.3, 19.7, and 0.7 pg/mL for cTnI, Mb, and CK‑MB, respectively. The smartphone‑based intelligent analyzer automates real-time signal processing, creating a closed-loop POC diagnostic setup that shows promise for future at‑home AMI risk monitoring. This technological breakthrough showcases notable resilience to biological matrix interference while upholding analytical sensitivity comparable to clinical standards, representing a significant step toward decentralized cardiovascular emergency management.
Beibei Lu, Huaibin Gong, Hua Huang, Kuaifa Fang, Kun Yu, Bitao Lu, et al. Smartphone-Enabled Point-of-Care Biosensing Platform With Self-Calibration for Rapid Matrix-Resistant Detection of Multiple AMI Biomarkers in Whole Blood.. Advanced healthcare materials. 2026; doi:10.1002/adhm.71408.
Beibei Lu, Huaibin Gong, Hua Huang, Kuaifa Fang, Kun Yu, Bitao Lu, et al (2026). Smartphone-Enabled Point-of-Care Biosensing Platform With Self-Calibration for Rapid Matrix-Resistant Detection of Multiple AMI Biomarkers in Whole Blood.. Advanced healthcare materials. https://doi.org/10.1002/adhm.71408
Beibei Lu, Huaibin Gong, Hua Huang, Kuaifa Fang, Kun Yu, Bitao Lu, et al. Smartphone-Enabled Point-of-Care Biosensing Platform With Self-Calibration for Rapid Matrix-Resistant Detection of Multiple AMI Biomarkers in Whole Blood.[J]. Advanced healthcare materials, 2026 doi:10.1002/adhm.71408.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出