一种重复经颅磁刺激-功能性近红外光谱系统:实现临床康复中神经可塑性的动态监测
A Repetitive Transcranial Magnetic Stimulation-Functional Near-Infrared Spectroscopy System: Achieving Dynamic Monitoring of Neuroplasticity in Clinical Rehabilitation.
A Repetitive Transcranial Magnetic Stimulation-Functional Near-Infrared Spectroscopy System: Achieving Dynamic Monitoring of Neuroplasticity in Clinical Rehabilitation.
本研究旨在将重复经颅磁刺激(rTMS)与功能性近红外光谱(fNIRS)相结合,实现对神经调控过程中神经活动的同步监测,并评估其在中风康复中的可行性。本研究针对中风神经调控领域长期缺乏同步反馈的问题,为开发自适应闭环神经康复技术提供了重要途径。rTMS在中风康复中的应用和优化受限于缺乏同步生理反馈,难以即时评估刺激疗效并调整治疗参数。现有将神经调控与神经影像相结合的技术往往缺乏验证,阻碍了其临床转化和广泛应用。本研究采用改进的fNIRS探头构建了能够在常规临床rTMS条件下进行近端检测的rTMS-fNIRS系统。通过磁干扰测试和仿真分析评估了系统伪迹、场穿透性和聚焦性。开展了为期14天的临床试验以验证系统的可行性和有效性。共纳入80例中风患者,采用小波振幅和偏侧化指数量化神经可塑性变化,同时应用临床量表评估行为学改善。工程验证表明,该系统能够在高强度刺激下稳定记录皮层血流动力学响应。同步临床监测显示,兴奋性rTMS诱导了皮层激活的动态增强和半球间再平衡,且这些神经生理学变化与上肢运动功能恢复的改善显著相关。所提出的rTMS-fNIRS系统不仅能够提供稳定的神经调控干预,还能在临床条件下同步监测刺激诱导的神经可塑性变化。
This study aimed to integrate repetitive transcranial magnetic stimulation (rTMS) with functional near-infrared spectroscopy (fNIRS) to achieve concurrent monitoring of neural activity during neuromodulation and to evaluate its feasibility in stroke rehabilitation. This work addresses the long-standing lack of concurrent feedback in stroke neuromodulation and provides an important pathway for developing adaptive, closed-loop neurorehabilitation technologies. The application and optimization of rTMS in stroke rehabilitation are constrained by the absence of concurrent physiological feedback, which limits timely evaluation of stimulation efficacy and adjustment of treatment parameters. Existing techniques combining neuromodulation with neuroimaging often lack validation, hindering their clinical translation and widespread application. This study employed improved fNIRS probes to construct an rTMS-fNIRS system capable of proximal detection under routine clinical rTMS conditions. Magnetic interference testing and simulation analyses were performed to evaluate system artifacts, field penetration, and focality. A 14-d clinical trial was conducted to verify the system's feasibility and effectiveness. A total of 80 patients with stroke were enrolled, and wavelet amplitude and laterality index were used to quantify neuroplasticity changes while clinical scales were applied to assess behavioral improvements. Engineering validation demonstrated that the system stably recorded cortical hemodynamic responses under high-intensity stimulation. Concurrent clinical monitoring revealed that excitatory rTMS induced dynamic enhancement of cortical activation and interhemispheric rebalancing, and these neurophysiological changes were significantly correlated with improvements in upper-limb motor recovery. The proposed rTMS-fNIRS system not only provides stable neuromodulatory intervention but also enables concurrent monitoring of stimulation-induced neuroplastic changes under clinical conditions.
Hui Xie, Yan Wang, Xin Li, Zengyong Li, Lin Wang, Gongcheng Xu, et al. A Repetitive Transcranial Magnetic Stimulation-Functional Near-Infrared Spectroscopy System: Achieving Dynamic Monitoring of Neuroplasticity in Clinical Rehabilitation.. BME frontiers. 2026; doi:10.34133/bmef.0283.
Hui Xie, Yan Wang, Xin Li, Zengyong Li, Lin Wang, Gongcheng Xu, et al (2026). A Repetitive Transcranial Magnetic Stimulation-Functional Near-Infrared Spectroscopy System: Achieving Dynamic Monitoring of Neuroplasticity in Clinical Rehabilitation.. BME frontiers. https://doi.org/10.34133/bmef.0283
Hui Xie, Yan Wang, Xin Li, Zengyong Li, Lin Wang, Gongcheng Xu, et al. A Repetitive Transcranial Magnetic Stimulation-Functional Near-Infrared Spectroscopy System: Achieving Dynamic Monitoring of Neuroplasticity in Clinical Rehabilitation.[J]. BME frontiers, 2026 doi:10.34133/bmef.0283.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出