Resolving the dilution paradox to improve the interpretation of extracellular vesicle biomarker studies.
Resolving the dilution paradox to improve the interpretation of extracellular vesicle biomarker studies.
细胞外囊泡(EVs)及其他颗粒的浓度在血浆中被检测以用于生物标志物探索。流式细胞术是一种常用方法,其需要稀释血浆以确保单颗粒检测。由于血浆中EVs的数量被浓度各异的脂蛋白所超过,不同血浆样本的稀释程度存在差异。稀释可导致将荧光背景信号误识别为标记的EVs。这种现象被称为稀释悖论,会导致血浆EV浓度的高估,并可能影响早期生物标志物研究的结论。本研究在考虑稀释悖论的情况下,重新评估了我们既往临床生物标志物研究——抗血小板治疗对细胞外囊泡的影响(AFFECT EV)和循环纳米示踪物识别卒中病因(CINTICS)——的结论。我们开发了一个模型,可量化荧光背景并评估流式细胞术检测是否以荧光背景为主,即该检测是否不可靠。该模型被应用于AFFECT EV和CINTICS研究的原始数据集,以识别并排除不可靠的检测。我们探究了排除不可靠数据是否影响原有结论。我们的模型估计,所评估的检测中有47%(1156/2457)不可靠,两项生物标志物研究的结论均需调整。我们的模型提高了使用流式细胞术进行EV浓度检测的可靠性和可重复性。我们建议使用我们的模型重新分析早期的EV流式细胞术研究,并在未来的EV流式细胞术研究中采用固定的稀释倍数,以实现可靠的EV浓度检测。
Concentrations of extracellular vesicles (EVs) and other particles are measured in plasma for biomarker exploration. A commonly used method, flow cytometry, requires plasma dilution to ensure single-particle detection. Since plasma EVs are outnumbered by variable concentrations of lipoproteins, dilution differs between the plasma samples. Dilution can result in misidentification of fluorescent background signals as labeled EVs. This phenomenon, called the dilution paradox, leads to overestimation of plasma EV concentrations, and likely impacts conclusions from earlier performed biomarker studies. This study reevaluated earlier conclusions from our clinical biomarker studies Antiplatelet Therapy Effect on Extracellular Vesicles (AFFECT EV) and Circulating Nanotraces to Identify the Cause of Stroke (CINTICS), by taking the dilution paradox into account. We developed a model that quantifies the fluorescent background and estimates whether a flow cytometry measurement is dominated by fluorescent background, that is, if the measurement is unreliable. This model was applied to the original datasets of the AFFECT EV and CINTICS studies to identify and exclude unreliable measurements. We investigated whether exclusion of unreliable data affects the original conclusions. Our model estimated that 47% (1156/2457) of the evaluated measurements are unreliable, and conclusions from both biomarker studies required adjustment. Our model improves reliability and reproducibility of EV concentration measurements using flow cytometry. We recommend to reanalyze earlier EV flow cytometry studies using our model and to use a fixed dilution factor in future EV flow cytometry studies to enable reliable EV concentration measurements.
Joyce Rops, Naomi C Buntsma, Aleksandra Gąsecka, Rienk Nieuwland, Aleksandra Rosiek, Yvo B W E M Roos, et al. Resolving the dilution paradox to improve the interpretation of extracellular vesicle biomarker studies.. Research and practice in thrombosis and haemostasis. 2026; doi:10.1016/j.rpth.2026.106636.
Joyce Rops, Naomi C Buntsma, Aleksandra Gąsecka, Rienk Nieuwland, Aleksandra Rosiek, Yvo B W E M Roos, et al (2026). Resolving the dilution paradox to improve the interpretation of extracellular vesicle biomarker studies.. Research and practice in thrombosis and haemostasis. https://doi.org/10.1016/j.rpth.2026.106636
Joyce Rops, Naomi C Buntsma, Aleksandra Gąsecka, Rienk Nieuwland, Aleksandra Rosiek, Yvo B W E M Roos, et al. Resolving the dilution paradox to improve the interpretation of extracellular vesicle biomarker studies.[J]. Research and practice in thrombosis and haemostasis, 2026 doi:10.1016/j.rpth.2026.106636.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出