多视角喉镜图像融合用于声带病变的患者级别分层

Multiview Laryngoscopic Image Fusion for Patient-Level Stratification of Vocal Fold Lesions.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

恶性或高级别声带病变通常需在不同观察距离和视野下反复行喉镜检查进行判断,而大多数人工智能系统仍基于单帧图像。本研究评估了多视角喉镜图像集的患者级融合是否能改善声带病变的良性 versus 恶性/高风险分层。在这项纳入628例患者的回顾性多中心研究中,来自中国医学科学院肿瘤医院2008年至2025年间收集的内部数据被分为训练队列(n=380)、验证队列(n=109)和内部测试队列(n=54),来自三家三级医院的外部临床队列纳入85例患者。在82例具有完整可评估模型输出的外部患者中计算了患者级融合性能。以集成学习和多实例学习作为对照,评估了病灶中心分割、候选卷积主干网络及患者级多视角融合。选择ResNet101作为帧级主干网络,第75百分位融合配置表现出最佳泛化能力。在外部可评估队列中,最终模型的AUC为0.890(95% CI,0.823-0.957),准确率为0.805(95% CI,0.706-0.876),灵敏度为0.643(95% CI,0.492-0.770),特异度为0.975(95% CI,0.871-0.996),PPV为0.964(95% CI,0.823-0.994),NPV为0.722(95% CI,0.591-0.824)。在所测试的策略中,患者级融合提供了最高的AUC点估计值,但主要的临床信号是极高的特异度而非排除性灵敏度。在当前操作点下,该模型不应作为独立的筛查或排除工具用于决定是否不进行活检;相反,应将其解释为活检前内镜分诊和恶性风险分层的辅助手段。

Abstract

Malignant or high-grade vocal fold disease is usually judged across repeated laryngoscopic views at different observation distances and fields of view, whereas most artificial intelligence systems remain frame-based. We evaluated whether patient-level fusion of multiview laryngoscopic image sets could improve benign versus malignant/high-risk stratification of vocal fold lesions. In this retrospective multicenter study of 628 patients, internal data from the Cancer Hospital and Institute of the Chinese Academy of Medical Sciences collected between 2008 and 2025 were split into training (n = 380), validation (n = 109), and internal test (n = 54) cohorts, and an external clinical cohort from three tertiary hospitals included 85 patients. Patient-level fusion performance was calculated in 82 external patients with complete evaluable model outputs. Lesion-centered segmentation, candidate convolutional backbones, and patient-level multiview fusion were evaluated against ensemble and multi-instance learning comparators. ResNet101 was selected as the frame-level backbone, and the 75th percentile fusion configuration showed the best generalization. In the external evaluable cohort, the final model achieved an AUC of 0.890 (95% CI, 0.823-0.957), accuracy of 0.805 (95% CI, 0.706-0.876), sensitivity of 0.643 (95% CI, 0.492-0.770), specificity of 0.975 (95% CI, 0.871-0.996), PPV of 0.964 (95% CI, 0.823-0.994), and NPV of 0.722 (95% CI, 0.591-0.824). Patient-level fusion provided the highest AUC point estimate among tested strategies, but the main clinical signal was very high specificity rather than rule-out sensitivity. At the present operating point, the model should not be used as a standalone screening or rule-out tool for deciding against biopsy; rather, it should be interpreted as an adjunct for endoscopic triage and malignant-risk stratification before biopsy.

如何引用

AMA

Jie-Lin Huang, Mei-Ling Wang, Li-Juan Li, Ying Li, Ji-Qing Zhu, Li-Zhou Dou, et al. Multiview Laryngoscopic Image Fusion for Patient-Level Stratification of Vocal Fold Lesions.. Journal of voice : official journal of the Voice Foundation. 2026; doi:10.1016/j.jvoice.2026.06.020.

APA

Jie-Lin Huang, Mei-Ling Wang, Li-Juan Li, Ying Li, Ji-Qing Zhu, Li-Zhou Dou, et al (2026). Multiview Laryngoscopic Image Fusion for Patient-Level Stratification of Vocal Fold Lesions.. Journal of voice : official journal of the Voice Foundation. https://doi.org/10.1016/j.jvoice.2026.06.020

GB/T 7714

Jie-Lin Huang, Mei-Ling Wang, Li-Juan Li, Ying Li, Ji-Qing Zhu, Li-Zhou Dou, et al. Multiview Laryngoscopic Image Fusion for Patient-Level Stratification of Vocal Fold Lesions.[J]. Journal of voice : official journal of the Voice Foundation, 2026 doi:10.1016/j.jvoice.2026.06.020.