用于纳米光学生物传感器评估的性价比指数:铕-水杨酸酯发光平台用于GPC3靶向早期HCC诊断的系统性评估

A cost-performance index for nano-optical biosensor evaluation: Systematic evaluation of europium-salicylate luminescent platforms for GPC3-targeted early HCC diagnosis.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

纳米光学生物传感器平台的比较评估缺乏一个标准化的、多参数定量框架,该框架需整合分析性能与实际可部署性——这是将实验室验证的传感器转化为资源受限临床环境应用的关键空白。本批判性综述通过提出十参数成本-性能指数(Cost-Performance Index, CPI)并将其应用于溶胶-凝胶和聚合物基质中的铕-水杨酸(Eu-SA)发光配合物来填补这一空白,该配合物作为一类新型、成本可及的光学生物传感器,用于时间分辨光学检测磷脂酰肌醇蛋白聚糖-3(GPC3)——一种早期肝细胞癌(HCC)血清生物标志物。本综述做出四项分析化学贡献:(i)CPI框架本身——据我们所知,这是首个可重复、源自文献的工具,在实验室加权和POC加权两种方案下,对七个生物传感器平台按十个参数(LOD、选择性、成本效益、POC就绪度、稳定性、临床转化就绪度、多重检测能力、样本制备、制造可扩展性和法规成熟度)进行评分,并报告所有原始评分以实现独立重算;(ii)首次对水杨酸作为低成本天线配体(<$0.05/g)进行系统机制表征,该配体通过高效的配体-金属能量转移赋予长发光寿命(>1 ms)和窄615 nm发射;(iii)对已发表的分子对接、MD和时域有限差分(FDTD)模拟结果作为计算设计预测进行透明综合,并明确区别于实验证实的结果;(iv)对Eu-SA GPC3生物传感器进入临床部署前必须弥合的转化证据空白进行结构化表征。通过对五个心肌肌钙蛋白I(cTnI)纳米生物传感器平台应用相同评分,展示了CPI框架的跨领域验证:所得POC加权排名与GPC3领域在结构上一致,证实了该框架在临床不同分析物和平台文献间的可推广性。Eu-SA GPC3生物传感器当前的证据基础仅包括在加标人血清和啮齿动物模型中的分析验证。尚无前瞻性多中心临床队列数据。本综述全文对此局限性进行了明确讨论。综述结论认为,Eu-SA平台代表一种有前景、成本可及的传感策略,值得严格的临床验证——而非在当前证据阶段已证明的优越性。披露:本文报告的Eu-SA GPC3生物传感器主要分析性能数据源自先前两项出版物,分别来自艾因夏姆斯大学(埃及开罗)和伊玛目穆罕默德·伊本·沙特伊斯兰大学(沙特阿拉伯利雅得)的实验室,上述机构均在本作者团队中。外部实验室尚未在同行评审文献中报告对这些数据的独立重复。因此,赋予Eu-SA平台的成本-性能指数排名仅作为所提出框架的示例性应用呈现,不应被解释为对平台优越性的确定性判定。

Abstract

Comparative evaluation of nano-optical biosensor platforms lacks a standardised, multi-parameter quantitative framework that integrates analytical performance with practical deployability - a critical gap for translating laboratory-validated sensors into resource-constrained clinical settings. This critical review addresses that gap by proposing a ten-parameter Cost-Performance Index (CPI) and applying it to europium-salicylate (Eu-SA) luminescent complexes in sol-gel and polymeric matrices as a novel, cost-accessible biosensor class for time-resolved optical detection of glypican-3 (GPC3), an early-stage hepatocellular carcinoma (HCC) serum biomarker. Four analytical chemistry contributions are made: (i) the CPI framework itself - to the best of our knowledge, the first reproducible, literature-derived instrument scoring seven biosensor platforms across ten parameters (LOD, selectivity, cost efficiency, POC readiness, stability, clinical translation readiness, multiplexing, sample preparation, fabrication scalability, and regulatory maturity) under both laboratory-weighted and POC-weighted schemes, with all raw scores reported to enable independent recalculation; (ii) the first systematic mechanistic characterisation of salicylic acid as a low-cost antenna ligand (<$0.05/g) conferring long luminescence lifetimes (>1 ms) and narrow 615 nm emission via efficient ligand-to-metal energy transfer; (iii) a transparent synthesis of published molecular docking, MD, and Finite-Difference Time-Domain (FDTD) simulation results as computa-tional design predictions, explicitly distinguished from experimentally confirmed outcomes; and (iv) a structured characterisation of the translational evidence gaps that must be closed before Eu-SA GPC3 biosensors can enter clinical deployment. Cross-domain validation of the CPI framework is demonstrated by applying identical scoring to five cardiac troponin I (cTnI) nano-biosensor platforms: the resulting POC-weighted rankings are structurally consistent with the GPC3 domain, confirming the framework's generalisability across clinically distinct analytes and platform lit-eratures. The current evidence base for Eu-SA GPC3 biosensors consists of analytical validation in spiked human serum and rodent models only. No prospective multi-centre clinical cohort data are available. This limitation is discussed explicitly throughout. The review concludes that Eu-SA platforms represent a promising, cost-accessible sensing strategy warranting rigorous clinical validation - not a demonstrated superiority at this stage of evi-dence. Disclosure: The primary analytical performance data for Eu-SA GPC3 biosensors reported herein derive from two prior publications originating from the laboratories of Ain Shams University (Cairo, Egypt) and Imam Mohammad Ibn Saud Islamic University (Riyadh, Saudi Arabia), institutions represented in this authorship. In-dependent replication of these data by external laboratories has not yet been reported in the peer-reviewed literature. Accordingly, the Cost-Performance Index ranking assigned to the Eu-SA platform is presented as an illustrative application of the proposed framework and should not be interpreted as a definitive determination of platform superiority.

如何引用

AMA

Youssef M Hassan, Hala El-Tantawi, Ibrahim Rabie Ali, Mohamed S Attia. A cost-performance index for nano-optical biosensor evaluation: Systematic evaluation of europium-salicylate luminescent platforms for GPC3-targeted early HCC diagnosis.. Talanta. 2027; doi:10.1016/j.talanta.2026.130103.

APA

Youssef M Hassan, Hala El-Tantawi, Ibrahim Rabie Ali, Mohamed S Attia (2027). A cost-performance index for nano-optical biosensor evaluation: Systematic evaluation of europium-salicylate luminescent platforms for GPC3-targeted early HCC diagnosis.. Talanta. https://doi.org/10.1016/j.talanta.2026.130103

GB/T 7714

Youssef M Hassan, Hala El-Tantawi, Ibrahim Rabie Ali, Mohamed S Attia. A cost-performance index for nano-optical biosensor evaluation: Systematic evaluation of europium-salicylate luminescent platforms for GPC3-targeted early HCC diagnosis.[J]. Talanta, 2027 doi:10.1016/j.talanta.2026.130103.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Talanta 的其他文献