一种高强度离心力增强的抗酸染色法用于提高结核分枝杆菌的检测效果
A high centrifugal force-enhanced Ziehl-Neelsen method for improved detection of Mycobacterium tuberculosis.
A high centrifugal force-enhanced Ziehl-Neelsen method for improved detection of Mycobacterium tuberculosis.
Ziehl-Neelsen(ZN)涂片显微镜检查仍然是结核病(TB)诊断和治疗监测的核心手段;然而,其敏感性受限于分析前处理过程中结核分枝杆菌回收不充分。本研究评估了改变离心力和离心时间是否能改善杆菌回收率和ZN涂片显微镜检查性能。采用结核分枝杆菌H37Rv悬液和临床痰标本进行实验室实验。经NALC-NaOH处理后,样品分别在2,000、3,000和6,000×g下离心40分钟。离心时间的影响在3,000×g下评估,通过比较20分钟和40分钟,使用相同的结核分枝杆菌H37Rv培养物和相同的临床痰标本在两个时间点进行检测,确保每种样品类型内进行配对测量。从重复涂片评估涂片阳性率和ZN涂片分级,并使用非参数统计检验进行分析,显著性设定为p < 0.05。在结核分枝杆菌H37Rv悬液中,不同离心力之间涂片阳性率或分级均未观察到显著差异(分别为p = 0.368和p = 0.212)。在临床痰标本中,不同离心力之间涂片阳性率无显著差异(p = 0.716),而ZN涂片分级随离心力增高而显著增加(p = 0.0051)。在3,000×g下,将离心时间从20分钟延长至40分钟对两种样品类型的涂片阳性率均无显著影响(均p = 1.000)。相反,随着离心时间延长,临床标本中ZN涂片分级从1+增至2+(p = 0.016),而结核分枝杆菌H37Rv悬液中未观察到变化。这些发现表明,增加离心力可能增强临床痰标本中的杆菌浓集,导致涂片分级改善,但检测率无相应增加。延长离心时间对涂片阳性率影响有限。优化分析前离心参数可能改善临床标本中ZN涂片显微镜检查的性能。
Ziehl-Neelsen (ZN) smear microscopy remains central to tuberculosis (TB) diagnosis and treatment monitoring; however, its sensitivity is limited by incomplete recovery of Mycobacterium tuberculosis during pre-analytical processing. This study evaluated whether modifying centrifugation force and duration improves bacillary recovery and ZN smear microscopy performance. Laboratory experiments were conducted using M. tuberculosis H37Rv suspensions and clinical sputum specimens. Following NALC-NaOH treatment, samples were centrifuged at 2,000, 3,000, and 6,000 × g for 40 min. The effect of centrifugation duration was assessed at 3,000 × g by comparing 20 and 40 min using the same M. tuberculosis H37Rv cultures and the same clinical sputum specimens at both time points, ensuring paired measurements within each sample type. Smear positivity and ZN smear grading were evaluated from replicate smears and analyzed using non-parametric statistical tests, with significance set at p < 0.05. In M. tuberculosis H37Rv suspensions, no significant differences in smear positivity or grading were observed across centrifugal forces (p = 0.368 and p = 0.212, respectively). In clinical sputum specimens, smear positivity did not differ significantly across forces (p = 0.716), whereas ZN smear grading increased significantly with higher centrifugal force (p = 0.0051). At 3,000 × g, extending centrifugation time from 20 to 40 min did not significantly affect smear positivity in either sample type (both p = 1.000). In contrast, ZN smear grading increased from 1+ to 2+ in clinical specimens with extended centrifugation time (p = 0.016), while no change was observed in M. tuberculosis H37Rv suspensions. These findings indicate that increasing centrifugal force may enhance bacillary concentration in clinical sputum, resulting in improved smear grading without a corresponding increase in detection rate. Extending centrifugation time has limited impact on smear positivity. Optimization of pre-analytical centrifugation parameters may improve ZN smear microscopy performance in clinical specimens.
Godlove T Chaula, Lucy Namkinga, Wilber Sabiiti, Nyanda E Ntiningya, Bariki Mtafya, Ally Mahadhy. A high centrifugal force-enhanced Ziehl-Neelsen method for improved detection of Mycobacterium tuberculosis.. PloS one. 2026; doi:10.1371/journal.pone.0342273.
Godlove T Chaula, Lucy Namkinga, Wilber Sabiiti, Nyanda E Ntiningya, Bariki Mtafya, Ally Mahadhy (2026). A high centrifugal force-enhanced Ziehl-Neelsen method for improved detection of Mycobacterium tuberculosis.. PloS one. https://doi.org/10.1371/journal.pone.0342273
Godlove T Chaula, Lucy Namkinga, Wilber Sabiiti, Nyanda E Ntiningya, Bariki Mtafya, Ally Mahadhy. A high centrifugal force-enhanced Ziehl-Neelsen method for improved detection of Mycobacterium tuberculosis.[J]. PloS one, 2026 doi:10.1371/journal.pone.0342273.