微重力下护理点肺超声的人工智能解释

Artificial Intelligence Interpretation of Point-of-Care Lung Ultrasound in Microgravity.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

长期太空任务需要可靠、便携且自主的医学诊断工具。肺部超声(LUS)因其安全性和多功能性而成为太空探索的理想选择,但解读LUS图像需要培训。人工智能(AI)可通过检测肺滑动来辅助图像解读,肺滑动是呼吸过程中肺与胸壁运动产生的超声征象。肺滑动的存在有助于排除气胸或肺萎陷,后者可能由气压伤或加压快速变化引起。在模拟微重力和月球重力的抛物线飞行机动过程中,从两名健康志愿者获取了LUS视频片段,并以+1-G片段作为对照。使用AI模型分析片段以分类肺滑动的存在,并比较不同重力条件下的模型性能和置信度。所有片段均由专家审阅以确定是否存在肺滑动,作为AI模型评估的参考标准。从105个LUS片段中,该模型表现出94%的准确率,在+1 G(96%)、月球重力(94%)和微重力(92%)下性能相似。预测置信度随重力变化,中位数在+1 G时为93%,月球重力时为83%,微重力时为67%。与+1 G相比,微重力下的置信度显著降低。这些发现表明,AI辅助LUS可在降低重力条件下可靠检测肺滑动,支持其作为航天自主诊断支持工具的可行性,并强调在微重力环境中进一步验证的重要性。Côté M, Smith D, Orozco N, VanBerlo B, Huggard B, Arntfield R, Prager R. Artificial intelligence interpretation of point-of-care lung ultrasound in microgravity. Aerosp Med Hum Perform. 2026; 97(7):505-509.

Abstract

Long-duration space missions demand reliable, portable, and autonomous medical diagnostic tools. Lung ultrasound (LUS) is ideal for space exploration due to its safety and versatility, but interpreting LUS images requires training. Artificial intelligence (AI) can assist with image interpretation by detecting lung sliding, an ultrasound sign produced by the movement of lung and chest wall during breathing. The presence of lung sliding helps to rule out pneumothorax, or a collapsed lung, which is a condition that may arise from barotrauma or rapid changes in pressurization. LUS clips were acquired from two healthy volunteers during parabolic flight maneuvers simulating microgravity and lunar gravity, with +1-G clips used as controls. Clips were analyzed using an AI model to classify the presence of lung sliding and model performance and confidence were compared across gravity conditions. All clips were reviewed by an expert to establish whether lung sliding was present, which served as the reference standard for AI model evaluation. From 105 LUS clips, the model demonstrated an accuracy of 94%, with similar performance at +1 G (96%), lunar gravity (94%), and microgravity (92%). Prediction confidence varied by gravity, with median values of 93% at +1 G, 83% at lunar gravity, and 67% at microgravity. Confidence was significantly lower in microgravity compared with +1 G. These findings demonstrate that AI-assisted LUS can reliably detect lung sliding under reduced gravity, supporting its feasibility as an autonomous diagnostic support tool for spaceflight and highlighting the importance of further validation in microgravity environments. Côté M, Smith D, Orozco N, VanBerlo B, Huggard B, Arntfield R, Prager R. Artificial intelligence interpretation of point-of-care lung ultrasound in microgravity. Aerosp Med Hum Perform. 2026; 97(7):505-509.

如何引用

AMA

Melissa Côté, Delaney Smith, Nicolas Orozco, Blake VanBerlo, Ben Huggard, Robert Arntfield, et al. Artificial Intelligence Interpretation of Point-of-Care Lung Ultrasound in Microgravity.. Aerospace medicine and human performance. 2026; doi:10.3357/AMHP.6852.2026.

APA

Melissa Côté, Delaney Smith, Nicolas Orozco, Blake VanBerlo, Ben Huggard, Robert Arntfield, et al (2026). Artificial Intelligence Interpretation of Point-of-Care Lung Ultrasound in Microgravity.. Aerospace medicine and human performance. https://doi.org/10.3357/AMHP.6852.2026

GB/T 7714

Melissa Côté, Delaney Smith, Nicolas Orozco, Blake VanBerlo, Ben Huggard, Robert Arntfield, et al. Artificial Intelligence Interpretation of Point-of-Care Lung Ultrasound in Microgravity.[J]. Aerospace medicine and human performance, 2026 doi:10.3357/AMHP.6852.2026.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Aerospace medicine and human performance 的其他文献