微重力下的闭合系统腰椎穿刺设计

A Closed-System Lumbar Puncture Design for Microgravity.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

腰椎穿刺(LP)是一种在地面用于多种疾病的诊断和治疗性操作,在人类航天微重力环境中还有额外应用。腰椎穿刺已在宇航员飞行后实施,以试图解答悬而未决的健康问题,例如航天相关神经眼综合征的病因。然而,由于该操作在微重力环境下的运行限制,包括感染风险、空气进入和液体管理困难,此前从未在太空或微重力环境中进行过腰椎穿刺。这阻碍了飞行中进行颅内压测量以及对航天飞行期间脑脊液(CSF)成分的重要表征。我们开发了一种封闭系统腰椎穿刺设计,在典型的针-针芯腰椎穿刺装置之间引入一个注射端口,并使用电子压力传感器(消除基于重力的测压法)。通过使用已知液体压力的腰椎穿刺训练模型进行模拟腰椎穿刺,对新装置进行了初步的概念验证演示。封闭系统腰椎穿刺成功演示,无液体流失至系统外,也无明显空气进入。在测量典型脑脊液范围8-15 mmHg的压力时,新的封闭系统显示出准确(r = 0.995)且精确(SD = 0.406 mmHg)的结果。这一初步演示是测试新型腰椎穿刺系统的第一步,该系统可降低航天飞行期间进行该操作的风险。飞行中进行腰椎穿刺将能够收集微重力下颅内压和脑脊液成分的重要数据。还需要开发定制设备并进行体内测试以进一步验证。Adams B, Levinson Z, Alexandrov P, Mampre D. A closed-system lumbar puncture design for microgravity. Aerosp Med Hum Perform. 2026; 97(7):534-538.

Abstract

A lumbar puncture (LP) is a diagnostic and therapeutic procedure for wide-ranging conditions terrestrially with additional applications in the microgravity environment of human spaceflight. LP has been performed on astronauts postflight in an attempt to answer lingering health questions, like the causes of spaceflight-associated neuro-ocular syndrome. However, an LP has not been performed in space or microgravity before due to the operational constraints of the procedure, including infection risk, air entrance, and fluid management difficulties in microgravity. This has prevented in-flight intracranial pressure measurements and important characterizations of cerebrospinal fluid (CSF) composition during spaceflight. We developed a closed-system LP design by introducing an injection port between the typical needle-stylet LP device and using an electronic pressure transducer (eliminating gravity-based manometry). An initial proof of concept demonstration of the new device was conducted by performing mock LPs using an LP trainer with known fluid pressures. Closed-system LP was successfully demonstrated with no loss of fluid external to the system and no appreciable entrance of air. The new closed system showed accurate (r = 0.995) and precise (SD = 0.406 mmHg) results when measuring pressures in the typical CSF range of 8-15 mmHg. This initial demonstration serves as the first step in testing a novel LP system that mitigates risks of conducting the procedure during spaceflight. An in-flight LP would enable the collection of vital data on intracranial pressure and CSF composition under microgravity. Development of custom equipment and in vivo testing are needed for further validation. Adams B, Levinson Z, Alexandrov P, Mampre D. A closed-system lumbar puncture design for microgravity. Aerosp Med Hum Perform. 2026; 97(7):534-538.

如何引用

AMA

Brandon Adams, Zoey Levinson, Peter Alexandrov, David Mampre. A Closed-System Lumbar Puncture Design for Microgravity.. Aerospace medicine and human performance. 2026; doi:10.3357/AMHP.6853.2026.

APA

Brandon Adams, Zoey Levinson, Peter Alexandrov, David Mampre (2026). A Closed-System Lumbar Puncture Design for Microgravity.. Aerospace medicine and human performance. https://doi.org/10.3357/AMHP.6853.2026

GB/T 7714

Brandon Adams, Zoey Levinson, Peter Alexandrov, David Mampre. A Closed-System Lumbar Puncture Design for Microgravity.[J]. Aerospace medicine and human performance, 2026 doi:10.3357/AMHP.6853.2026.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Aerospace medicine and human performance 的其他文献