[电阻抗断层扫描引导机械通气患者气道清除的安全性和有效性]
[Safety and efficacy of electrical impedance tomography-guided airway clearance in mechanically ventilated patients].
[Safety and efficacy of electrical impedance tomography-guided airway clearance in mechanically ventilated patients].
评估电阻抗断层成像(EIT)引导的气道廓清方案在机械通气患者中的安全性和有效性。纳入2024年1月至2025年4月北京市两家三级甲等医院重症监护病房收治的62例机械通气患者。将患者分为两组:干预组(=31)接受EIT引导的气道廓清,对照组(=31)根据入院时胸部CT结果接受常规气道廓清。比较两组气道廓清的有效性和安全性。采用SPSS 26.0进行统计分析。干预组全局不均匀性指数(GI)从第1天至第7天显著改善(0.45±0.14 0.36±0.05,=2.060,<0.05)。第1天,腹侧区域左右通气分布差异在廓清后10分钟和30分钟较廓清前显著减小(9.19%±8.29%、8.41%±7.92% 14.03%±8.35%)。背侧区域左右通气分布差异在廓清后1小时较廓清前显著降低(7.09%±5.50% 10.32%±7.24%)。廓清后30分钟和1小时,通气中心(49.45±3.16、49.00±3.65 45.80±5.91)和GI(0.39±0.05、0.39±0.07 0.45±0.14)较廓清前显著改善(均P<0.05)。第7天,左右腹侧通气分布差异在廓清后10分钟、30分钟和1小时较廓清前显著减小(8.32%±7.11%、6.48%±6.94%、5.90%±6.05% 12.32%±9.66%)。治疗两周后,两组胸部CT高密度影面积均缩小,干预组缩小更为明显(<0.05)。干预组第7天每日痰量显著少于对照组(55.48±14.28 ml 80.00±22.77 ml),且第5天和第7天痰液黏度分布改善更明显(<0.05)。治疗后,干预组氧合指数升高幅度(286.88±81.97 mmHg 223.00±73.82 mmHg)和白细胞计数下降幅度[(11.01±5.48)×10/L (13.88±4.95)×10/L]均大于对照组(均<0.05)。干预组气道廓清总次数(12.23±2.80 14.00±0.00)和机械通气时间(12.55±5.18天 16.29±8.75天)均显著低于对照组(均<0.05)。操作过程中两组均未发生导管移位、脱出或大咯血等不良事件。EIT引导的气道廓清方案在机械通气患者中安全有效,可为该情境下气道廓清策略的选择和疗效评估提供科学依据。
To evaluate the safety and efficacy of an electrical impedance tomography (EIT)-guided airway clearance protocol in mechanically ventilated patients. A total of 62 mechanically ventilated patients admitted to the intensive care units of two tertiary Grade A hospitals in Beijing between January 2024 and April 2025 were enrolled. Patients were allocated into two groups: the intervention group (=31) received EIT-guided airway clearance, while the control group (=31) received conventional airway clearance based on admission chest CT findings. Airway clearance efficacy and safety were compared between the two groups. Statistical analysis was performed using SPSS 26.0. In the intervention group, the global inhomogeneity index (GI) improved significantly from day 1 to day 7 (0.45±0.14 0.36±0.05, =2.060, <0.05). On day 1, the left-right ventilation distribution difference in the ventral region was significantly reduced at 10 minutes and 30 minutes post-clearance compared with pre-clearance (9.19%±8.29%, 8.41%±7.92% 14.03%±8.35%). The left-right ventilation distribution difference in the dorsal region was significantly lower at 1 hour post-clearance compared with pre-clearance (7.09%±5.50% 10.32%±7.24%). At 30 minutes and 1 hour post-clearance, the center of ventilation (49.45±3.16, 49.00±3.65 45.80±5.91) and the GI (0.39±0.05, 0.39±0.07 0.45±0.14) were significantly improved compared with pre-clearance (all P<0.05). On day 7, the left-right ventral ventilation distribution difference was significantly reduced at 10 minutes, 30 minutes, and 1 hour post-clearance compared with pre-clearance (8.32%±7.11%, 6.48%±6.94%, 5.90%±6.05% 12.32%±9.66%). The area of high-density opacities on chest CT was reduced in both groups after two weeks of treatment, with a more pronounced reduction in the intervention group (<0.05). The intervention group had significantly less daily sputum output on day 7 than the control group (55.48±14.28 ml 80.00±22.77 ml), and demonstrated greater improvement in sputum viscosity distribution on days 5 and 7 (<0.05). After treatment, the intervention group showed a greater increase in the oxygenation index (286.88±81.97 mmHg . 223.00±73.82 mmHg) and a greater decrease in leukocyte count [(11.01±5.48)×10/L (13.88±4.95)×10/L] than the control group (both <0.05).The total number of airway clearance sessions (12.23±2.80 14.00±0.00) and the duration of mechanical ventilation (12.55±5.18 days 16.29±8.75 days) were significantly lower in the intervention group than in the control group (both <0.05). No adverse events, including catheter displacement, dislodgement or massive haemoptysis, occurred in either group during the procedure. The EIT-guided airway clearance protocol is safe and effective in mechanically ventilated patients, providing a scientific basis for the selection and efficacy evaluation of airway clearance strategies in this setting.
H J Gu, X N Yuan, B Shen, Q Y Yang, F Xie, Y L Ma. [Safety and efficacy of electrical impedance tomography-guided airway clearance in mechanically ventilated patients].. Zhonghua jie he he hu xi za zhi = Zhonghua jiehe he huxi zazhi = Chinese journal of tuberculosis and respiratory diseases. 2026; doi:10.3760/cma.j.cn112147-20251209-00775.
H J Gu, X N Yuan, B Shen, Q Y Yang, F Xie, Y L Ma (2026). [Safety and efficacy of electrical impedance tomography-guided airway clearance in mechanically ventilated patients].. Zhonghua jie he he hu xi za zhi = Zhonghua jiehe he huxi zazhi = Chinese journal of tuberculosis and respiratory diseases. https://doi.org/10.3760/cma.j.cn112147-20251209-00775
H J Gu, X N Yuan, B Shen, Q Y Yang, F Xie, Y L Ma. [Safety and efficacy of electrical impedance tomography-guided airway clearance in mechanically ventilated patients].[J]. Zhonghua jie he he hu xi za zhi = Zhonghua jiehe he huxi zazhi = Chinese journal of tuberculosis and respiratory diseases, 2026 doi:10.3760/cma.j.cn112147-20251209-00775.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出