定制富胺多孔整体材料用于酚类环境雌激素的微型化固相萃取

Tailoring amine-rich porous monolith for the miniaturized solid phase extraction of phenolic environmental estrogens.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

开发一种高效的小型化固相萃取(μ-SPE)方法对于准确、可靠地监测环境水体中的痕量酚类环境雌激素(PEEs)至关重要。本研究开发了一种实验室自制的多通道枪头内微萃取装置(MIMA),该装置将富含胺基的多孔整体材料(APA)原位形成于移液枪头(200 μL)内,用于高效捕获环境水体中的PEEs。由于含有丰富的氨基基团,APA通过多种相互作用表现出令人满意的微萃取性能。最大吸附量和萃取效率分别为2.63-10.0 mg/g和70.9-95.8%。同时,APA展现出优异的批次间制备重现性,RSD范围为2.8%-8.6%,并具有良好的重复使用性(至少可重复使用40次)。此外,系统研究了其吸附特性和微萃取机理。在最有利的微萃取参数下,所建立的APA@MIMA方法能够在HPLC/DAD测定之前对水样中目标PEEs进行现场样品前处理,具有宽线性范围、低检出限(0.0023-0.013 μg/L)和令人满意的方法精密度(RSD低于10%)。验证实验和加标回收率进一步证实了该方法的准确性。此外,基于样品前处理分析绿色度评估、绿色度评估和绿色分析过程指数对方法绿色度进行了综合评价,相应数值分别为0.64、0.50和79。本研究突出了APA@MIMA技术在环境水体中PEEs现场萃取方面的应用前景,同时克服了实验室样品前处理方法的局限性。

Abstract

Developing an efficient miniaturized solid phase extraction (μ-SPE) method is essential in the accurate and reliable monitoring of trace phenolic environmental estrogens (PEEs) in environmental waters. In this study‌, a lab-built multichannel in-tip microextraction apparatus (MIMA) incorporating an amine-rich porous monolith (APA) formed in situ within a pipette tip (200 μL) was developed for efficient capture of PEEs in environmental waters. Due to the abundant amino groups, the APA exhibited satisfactory microextraction performance through multiple interactions. The maximum adsorption amounts and extraction efficiencies were in the ranges of 2.63-10.0 mg/g and 70.9-95.8%, respectively. At the same time, the APA presented excellent batch-to-batch preparation reproducibility with the RSDs varied from 2.8% to 8.6% and satisfactory reusability (could be reapplied at least 40 times). Furthermore, the adsorption characteristic and microextraction mechanism were systematically investigated. Under the most beneficial microextraction parameters, the established APA@MIMA method enabled on-field sample preparation of the studied PEEs in waters prior to HPLC/DAD determination, offering wide working ranges, low limits of detection (0.0023-0.013 μg/L) and satisfactory method precision (RSDs below 10%). Confirmatory experiments and fortifying recovery further validated the method accuracy. Additionally, method greenness was comprehensively assessed based on analytical GREEnness for sample preparation, assessment of greenness and green analytical process index, and the corresponding values were 0.64, 0.50 and 79. The present work highlights the promising application of APA@MIMA technique in the on-site extraction of PEEs in environmental waters while overcoming the limitations of lab-based sample preparation methods.

如何引用

AMA

Yutong Yu, Yufeng Zeng, Dingling Tang, Yuanfei Wu, Xiaojia Huang. Tailoring amine-rich porous monolith for the miniaturized solid phase extraction of phenolic environmental estrogens.. Talanta. 2027; doi:10.1016/j.talanta.2026.130210.

APA

Yutong Yu, Yufeng Zeng, Dingling Tang, Yuanfei Wu, Xiaojia Huang (2027). Tailoring amine-rich porous monolith for the miniaturized solid phase extraction of phenolic environmental estrogens.. Talanta. https://doi.org/10.1016/j.talanta.2026.130210

GB/T 7714

Yutong Yu, Yufeng Zeng, Dingling Tang, Yuanfei Wu, Xiaojia Huang. Tailoring amine-rich porous monolith for the miniaturized solid phase extraction of phenolic environmental estrogens.[J]. Talanta, 2027 doi:10.1016/j.talanta.2026.130210.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Talanta 的其他文献