基于数字算法的压力痛阈测量在终末期膝骨性关节炎患者中的可靠性:一项单中心可靠性研究

Reliability of digital algometer-based pressure pain threshold measurement in patients with end-stage knee osteoarthritis: a single-center reliability study.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

评估基于数字压痛仪的压力痛阈值(PPT)测量在终末期膝骨关节炎(KOA)患者中的信度与测量误差。本前瞻性观察性信度研究纳入60例拟行全膝关节置换术的终末期KOA患者。由两名经验水平不同的评估者在基线及7天后,按照标准化培训和测量流程,于患膝内侧(局部部位)和对侧前臂背侧(远端部位)评估压力痛阈值。每次评估每个部位重复测量三次并取平均值。相对信度采用组内相关系数(ICC)评估,其中基于三次重复测量均值的组内信度采用ICC2,k模型,组间信度和评估者间信度采用ICC2,1模型。绝对测量误差采用测量标准误(SEM)、相对SEM(SEM%)以及95%置信水平下的最小可检测变化(MDC)进行量化。评估者间一致性采用Bland-Altman分析检验。压力痛阈值测量在所有条件下均表现出优良的信度。组内、组间及评估者间ICC值均超过0.87。组内ICC2,k值为0.874至0.965,组间ICC2,1值为0.870至0.984,评估者间ICC2,1值为0.921至0.953。相对SEM值均低于7%,组间MDC为0.33至0.72 kg/cm,代表检测超出随机变异的变化所需的测量误差阈值。Bland-Altman分析显示,大多数差值位于95%一致性界限内,无明显比例偏倚。评估者间平均差值为0.09至0.19 kg/cm。在标准化条件下,基于数字压痛仪的PPT评估在终末期KOA患者中表现出高信度和低测量误差。其临床实用性尚需进一步验证。

Abstract

To evaluate the reliability and measurement error of digital algometer-based pressure pain threshold (PPT) assessment inpatients with end-stage knee osteoarthritis (KOA). This prospective observational reliability study included 60 patients with end-stage KOA scheduled for total knee arthroplasty. Pressure pain threshold was assessed by two raters with different levels of experience at baseline and 7 days later at the medial aspect of the affected knee (local site) and the dorsal aspect of the contralateral forearm (remote site), following standardized training and measurement procedures. Three repeated measurements were obtained at each site per session and averaged. Relative reliability was assessed using intraclass correlation coefficients (ICC), with the ICC2,k model used for intra-session reliability based on the mean of three repeated measurements and the ICC2, 1 model used for inter-session and inter-rater reliability. Absolute measurement error was quantified using the standard error of measurement (SEM), relative SEM (SEM%), and the minimal detectable change at the 95% confidence level (MDC). Inter-rater agreement was examined using Bland - Altman analysis. Pressure pain threshold measurements demonstrated excellent reliability across all conditions. Intra-session, inter-session, and inter-rater ICC values all exceeded 0.87. Intra-session ICC2, k values ranged from 0.874 to 0.965, inter-session ICC2, 1 values from 0.870 to 0.984, and inter-rater ICC2, 1 values from 0.921 to 0.953. Relative SEM values remained below 7%, and inter-session MDC ranged from 0.33 to 0.72 kg/cm, representing measurement-error thresholds for detecting change beyond random variability. Bland-Altman analysis showed that most differences lay within the 95% limits of agreement, with no apparent proportional bias. Mean inter-rater differences ranged from 0.09 to 0.19 kg/cm. Under standardized conditions, digital algometer-based PPT assessment showed high reliability with low measurement error in patients with end-stage KOA. Clinical utility requires further validation.

如何引用

AMA

Zhiheng Hu, Xiaofeng Chang, Shuxin Yao, Feng Ye, Chao Xu, Jianbing Ma. Reliability of digital algometer-based pressure pain threshold measurement in patients with end-stage knee osteoarthritis: a single-center reliability study.. Physiotherapy theory and practice. 2026; doi:10.1080/09593985.2026.2695769.

APA

Zhiheng Hu, Xiaofeng Chang, Shuxin Yao, Feng Ye, Chao Xu, Jianbing Ma (2026). Reliability of digital algometer-based pressure pain threshold measurement in patients with end-stage knee osteoarthritis: a single-center reliability study.. Physiotherapy theory and practice. https://doi.org/10.1080/09593985.2026.2695769

GB/T 7714

Zhiheng Hu, Xiaofeng Chang, Shuxin Yao, Feng Ye, Chao Xu, Jianbing Ma. Reliability of digital algometer-based pressure pain threshold measurement in patients with end-stage knee osteoarthritis: a single-center reliability study.[J]. Physiotherapy theory and practice, 2026 doi:10.1080/09593985.2026.2695769.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Physiotherapy theory and practice 的其他文献