利用串联荧光适配体实现抗生素的信号放大无细胞生物传感
Signal-amplified cell-free biosensing of antibiotics using tandem fluorescent aptamers.
Signal-amplified cell-free biosensing of antibiotics using tandem fluorescent aptamers.
基于转录因子的无细胞生物传感器在快速、便携的抗生素检测方面具有吸引力,但其性能往往受限于灵敏度不足和背景信号较高。在此,我们利用RNA荧光适配体开发了增强型无细胞生物传感器,并评估了Pepper-HBC620系统作为低背景、高信噪比报告系统相较于广泛使用的Broccoli适配体的表现。为克服固有的灵敏度限制,采用了两种互补策略。首先,在保持恒定摩尔比的同时同步降低DNA模板和转录因子的浓度,有效降低了红霉素和四环素的激活阈值。其次,设计了串联荧光适配体模块(4×Broccoli和8×Pepper)作为无酶信号放大器。RNA二级结构预测和体外转录证实,串联构建体保持了正确的折叠,并显示出与适配体拷贝数成正比的荧光强度,且不改变激发或发射波长。通过整合这些策略,在显著减少DNA模板和调控蛋白用量的情况下获得了强荧光输出。优化后的mphO-4×Broccoli生物传感器对红霉素的检测限达到0.1 μM,而tetO-8×Pepper系统实现了低至0.05 μM的四环素检测,且响应时间缩短。总体而言,本研究建立了基于串联RNA适配体的无细胞生物传感器用于灵敏的抗生素检测。
Transcription factor-based cell-free biosensors are attractive for rapid and portable antibiotic detection, yet their performance is often constrained by limited sensitivity and high background signals. Here, we developed enhanced cell-free biosensors using RNA fluorescent aptamers and evaluated the Pepper-HBC620 system as a low-background, high-signal-to-noise reporter compared with the widely used Broccoli aptamer. To overcome intrinsic sensitivity limitations, two complementary strategies were employed. First, the concentrations of DNA templates and transcription factors were simultaneously reduced while maintaining constant molar ratios, which effectively lowered the activation thresholds for erythromycin and tetracycline. Second, tandem fluorescent aptamer modules (4×Broccoli and 8×Pepper) were designed as enzyme-free signal amplifiers. RNA secondary structure prediction and in vitro transcription confirmed that the tandem constructs preserved proper folding and displayed fluorescence intensities proportional to aptamer copy number without altering excitation or emission wavelengths. By integrating these strategies, strong fluorescence outputs were obtained with substantially reduced amounts of DNA templates and regulatory proteins. The optimized mphO-4×Broccoli biosensor achieved a detection limit of 0.1 μM for erythromycin, while the tetO-8×Pepper system enabled tetracycline detection down to 0.05 μM with a shortened response time. Overall, this study establishes tandem RNA aptamer-based cell-free biosensors for sensitive antibiotic detection.
Rongxin Cui, Baoyue Zhang, Zhiyuan Chang, Meilun Wang, Shengyu Yuan, Xingshuo Wang, et al. Signal-amplified cell-free biosensing of antibiotics using tandem fluorescent aptamers.. Talanta. 2027; doi:10.1016/j.talanta.2026.130226.
Rongxin Cui, Baoyue Zhang, Zhiyuan Chang, Meilun Wang, Shengyu Yuan, Xingshuo Wang, et al (2027). Signal-amplified cell-free biosensing of antibiotics using tandem fluorescent aptamers.. Talanta. https://doi.org/10.1016/j.talanta.2026.130226
Rongxin Cui, Baoyue Zhang, Zhiyuan Chang, Meilun Wang, Shengyu Yuan, Xingshuo Wang, et al. Signal-amplified cell-free biosensing of antibiotics using tandem fluorescent aptamers.[J]. Talanta, 2027 doi:10.1016/j.talanta.2026.130226.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出