溶解型微针阵列尺寸影响剂量节省疫苗接种的物理佐剂效应
Dissolving microneedle array size influences physical adjuvanticity for dose-sparing vaccination.
Dissolving microneedle array size influences physical adjuvanticity for dose-sparing vaccination.
溶解微针(DMNs)是一种新兴的用于经皮疫苗接种的生物材料平台,能够将抗原精确递送至富含抗原提呈细胞的皮肤层。在本研究中,我们发现了DMNs一种此前未被充分认识的大小依赖性免疫调节生物材料功能:其通过可控的组织微损伤充当物理佐剂的能力。微针插入产生空间分布的瞬态皮肤微损伤,诱导损伤相关分子模式的释放,其中以高迁移率族蛋白B1(HMGB-1)最为显著,从而建立一个局部炎症场,将机械输入与免疫激活相连接。重要的是,该反应的强度在数量上受微针阵列尺寸的调控,揭示器件结构是可调节生物学结果的可调设计参数。阵列尺寸依赖性微损伤促进了树突状细胞活化和淋巴迁移,从而增强了体液免疫应答,包括抗原特异性IgG滴度升高和浆细胞频率增加,即使在无外源性佐剂的情况下亦然。尽管先天免疫激活强烈,DMN诱导的炎症为局部性并在一周内完全消退,显示出良好的组织相容性。总体而言,这些发现确立了微针阵列设计作为一种可控的基于生物材料的策略,用以编程物理佐剂性,从而实现安全、无佐剂且节省剂量的疫苗接种。
Dissolving microneedles (DMNs) are an emerging biomaterial platform for transdermal vaccination, enabling precise antigen delivery into antigen-presenting cell-rich skin layers. Here, we identify a previously underappreciated size dependent immunomodulatory biomaterial function of DMNs: their ability to act as physical adjuvants through controlled tissue micro-injury. Microneedle insertion generates spatially distributed and transient skin micro-injury that induces the release of damage-associated molecular patterns, prominently high-mobility group box 1 (HMGB-1), thereby establishing a localized inflammatory field that bridges mechanical input to immune activation. Importantly, the magnitude of this response is quantitatively governed by microneedle array size, revealing device architecture as a tunable design parameter for modulating biological outcomes. Array size-dependent micro-injury promoted dendritic cell activation and lymphatic trafficking, resulting in enhanced humoral responses, including elevated antigen-specific IgG titers and increased plasma cell frequencies, even in the absence of exogenous adjuvants. Despite robust innate activation, DMN-induced inflammation was localized and fully resolved within one week, demonstrating favorable tissue compatibility. Collectively, these findings establish microneedle array design as a controllable biomaterial-based strategy to program physical adjuvanticity, enabling safe, adjuvant-free, and dose-sparing vaccination.
Hye Su Min, Youjin Lee, Sung Min Cho, Soyeon Park, Jeehye Nam, Hye In Oh, et al. Dissolving microneedle array size influences physical adjuvanticity for dose-sparing vaccination.. Biomaterials. 2026; doi:10.1016/j.biomaterials.2026.124400.
Hye Su Min, Youjin Lee, Sung Min Cho, Soyeon Park, Jeehye Nam, Hye In Oh, et al (2026). Dissolving microneedle array size influences physical adjuvanticity for dose-sparing vaccination.. Biomaterials. https://doi.org/10.1016/j.biomaterials.2026.124400
Hye Su Min, Youjin Lee, Sung Min Cho, Soyeon Park, Jeehye Nam, Hye In Oh, et al. Dissolving microneedle array size influences physical adjuvanticity for dose-sparing vaccination.[J]. Biomaterials, 2026 doi:10.1016/j.biomaterials.2026.124400.