一种用于同时冷却液滴和蒸发样品以提取挥发性组分的新型装置,采用冷却侧臂管顶空微萃取技术

A new device for simultaneous cooling of the drop and evaporated sample for the extraction of volatile components using cooled side arm tube headspace microextraction.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

一种新型冷却侧臂管顶空单滴微萃取(CSAT-HS-SDME)方法已成功应用于孜然芹(Carum copticum)挥发性成分的萃取。本研究旨在设计并制作一种可同时冷却萃取液滴与蒸发样品的新型装置。通过萃取并采用气相色谱-质谱联用仪(GC-MS)测定孜然芹样品中的对伞花烃、γ-松油烯和百里香酚,对该创新技术进行了评价。采用单纯形法对有效萃取参数进行了优化。在优化条件下(即冷端与热端温度分别为-10°C和70°C;加水体积20 μL;萃取时间20 min),5次重复所得峰面积的相对标准偏差在3.62%至4.69%之间。与其他同类用于冷却萃取相并同时加热样品的设备相比,该装置具有操作简单、成本极低、使用方便、便于携带等优点,且无需液体二氧化碳钢瓶或加热搅拌器等额外设备。所提出的方法已成功应用于部分孜然芹样品挥发性成分的萃取与鉴定。

Abstract

A new cooled side arm tube headspace single drop microextraction (CSAT-HS-SDME) method was successfully applied to the extraction of Carum copticum volatile components. The aim of this research is to design and fabricate a new device for simultaneous cooling of the drop and evaporated sample. The innovated technique was evaluated by the extraction and Gas chromatography-mass spectrometer (GC-MS) determination of p-cymene, γ-terpinene and thymol in C. copticum samples. Optimization of the effective extraction parameters was carried out by the simplex method. Under the optimized conditions (i.e. cold and heat temperature, -10°C and 70°C; water addition, 20 μL and extraction time, 20 min), the relative standard deviations of peak areas obtained from five replications were between 3.62% and 4.69%. Compared to other similar equipment for cooling the extraction phase and simultaneously heating the sample, this device has advantages such as simplicity, very low cost, ease of use, portability and no need for additional equipment such as a liquid carbon dioxide cylinder or heater-stirrer. The proposed method was successfully applied to the extraction and identification of volatile components of some C. copticum samples.

如何引用

AMA

Hamzeh Adelpour Abdoli, Kamal Alizadeh, Payman Hashemi. A new device for simultaneous cooling of the drop and evaporated sample for the extraction of volatile components using cooled side arm tube headspace microextraction.. Journal of chromatographic science. 2026; doi:10.1093/chromsci/bmag020.

APA

Hamzeh Adelpour Abdoli, Kamal Alizadeh, Payman Hashemi (2026). A new device for simultaneous cooling of the drop and evaporated sample for the extraction of volatile components using cooled side arm tube headspace microextraction.. Journal of chromatographic science. https://doi.org/10.1093/chromsci/bmag020

GB/T 7714

Hamzeh Adelpour Abdoli, Kamal Alizadeh, Payman Hashemi. A new device for simultaneous cooling of the drop and evaporated sample for the extraction of volatile components using cooled side arm tube headspace microextraction.[J]. Journal of chromatographic science, 2026 doi:10.1093/chromsci/bmag020.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI