五年患者报告了使用聚氨酯涂层植入物进行初次乳房增强术后的结果:一种特定器械的开发和初步验证

Five-year Patient-reported Outcomes Following Primary Breast Augmentation With Polyurethane-coated Implants: Development and Preliminary Validation of a Device-specific Instrument.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

初次美容性乳房隆乳术后的长期患者报告结局仍未被充分描述,尤其是在接受聚氨酯涂层假体的队列中。尽管经过验证的通用量表被广泛使用,但更广泛的结果测量可能无法完全捕捉器械特异性的患者感知。旨在评估使用聚氨酯涂层假体进行初次乳房隆乳术后五年的患者报告结局,并开发及初步验证一种器械特异性患者报告结局量表。开展了一项回顾性队列研究,纳入110例连续接受聚氨酯涂层假体初次美容性乳房隆乳术的患者。在平均5.2±0.8年的随访中,患者完成了一份15个条目的聚氨酯假体特异性患者报告结局量表(PU-PRO),评估感知、美学满意度和术后体验。心理测量学评价包括内容效度评估、内部一致性分析、探索性因子分析,以及采用组内相关系数(ICC)评估8个月间隔的重测信度。99例患者(90%)完成了5年评估,87例(88%)完成了8个月再评估。平均评分(0-100分)为:感知81.3±12.8,满意度84.5±11.9,体验78.2±14.3。1例患者(1%)报告有临床明显的波纹征,随访期间未发生翻修手术。各领域的Cronbach's α范围为0.84至0.91。探索性因子分析支持三因子结构,解释总方差的68%。ICC值为0.88至0.93,显示高度的时间稳定性。在该队列中,使用聚氨酯涂层假体进行初次乳房隆乳术在五年随访时显示出持续高水平的患者报告满意度。PU-PRO量表显示出信度和结构效度的初步证据。有必要开展进一步的前瞻性研究,纳入经过验证的比较性量表。

Abstract

Long-term patient-reported outcomes after primary aesthetic breast augmentation remain incompletely characterized, particularly in cohorts receiving polyurethane-coated implants. Although validated generic instruments are widely used, device-specific patient perception may not be fully captured by broader outcome measures. To evaluate five-year patient-reported outcomes following primary breast augmentation with polyurethane-coated implants and to develop and preliminarily validate a device-specific patient-reported outcome instrument. A retrospective cohort study was conducted including 110 consecutive patients who underwent primary aesthetic breast augmentation with polyurethane-coated implants. At a mean follow-up of 5.2 ± 0.8 years, patients completed a 15-item polyurethane implant-specific patient-reported outcome instrument (PU-PRO) assessing Perception, Aesthetic Satisfaction, and Postoperative Experience. Psychometric evaluation included content validity assessment, internal consistency analysis, exploratory factor analysis, and test-retest reliability over an 8-month interval using intraclass correlation coefficients (ICC). Ninety-nine patients (90%) completed the 5-year assessment, and 87 (88%) completed the 8-month reassessment. Mean scores (0-100 scale) were 81.3 ± 12.8 for Perception, 84.5 ± 11.9 for Satisfaction, and 78.2 ± 14.3 for Experience. One patient (1%) reported clinically evident rippling, and no revision surgeries occurred during follow-up. Cronbach's alpha ranged from 0.84 to 0.91 across domains. Exploratory factor analysis supported a three-factor structure explaining 68% of total variance. ICC values ranged from 0.88 to 0.93, demonstrating high temporal stability. Primary breast augmentation with polyurethane-coated implants demonstrated sustained high levels of patient-reported satisfaction at five-year follow-up in this cohort. The PU-PRO instrument showed preliminary evidence of reliability and construct validity. Further prospective studies incorporating validated comparative instruments are warranted.

如何引用

AMA

Sergio Burciaga Soto, Norman Alejandro Rendón Mejía. Five-year Patient-reported Outcomes Following Primary Breast Augmentation With Polyurethane-coated Implants: Development and Preliminary Validation of a Device-specific Instrument.. Aesthetic surgery journal. 2026; doi:10.1093/asj/sjag129.

APA

Sergio Burciaga Soto, Norman Alejandro Rendón Mejía (2026). Five-year Patient-reported Outcomes Following Primary Breast Augmentation With Polyurethane-coated Implants: Development and Preliminary Validation of a Device-specific Instrument.. Aesthetic surgery journal. https://doi.org/10.1093/asj/sjag129

GB/T 7714

Sergio Burciaga Soto, Norman Alejandro Rendón Mejía. Five-year Patient-reported Outcomes Following Primary Breast Augmentation With Polyurethane-coated Implants: Development and Preliminary Validation of a Device-specific Instrument.[J]. Aesthetic surgery journal, 2026 doi:10.1093/asj/sjag129.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Aesthetic surgery journal 的其他文献