联合白内障手术和后弹力膜内皮角膜移植术中基于光线追踪的人工晶状体度数计算
Ray-Tracing-Based Intraocular Lens Power Calculation in Combined Cataract Surgery and Descemet Membrane Endothelial Keratoplasty.
Ray-Tracing-Based Intraocular Lens Power Calculation in Combined Cataract Surgery and Descemet Membrane Endothelial Keratoplasty.
比较基于光线追踪的人工晶状体(IOL)屈光度计算公式与Barrett Universal II(BUII)公式在合并白内障手术及后弹力层内皮角膜移植术(三联DMEK)的Fuchs内皮角膜营养不良(FECD)眼中的预测准确性。这是一项回顾性、单中心比较性病例系列研究。术前生物测量采用Scheimpflug断层扫描(Pentacam AXL)和基于扫频源光学相干断层扫描的生物测量仪(IOLMaster 700)获取。IOL屈光度计算采用Barrett Universal II(BUII)、Olsen光线追踪以及两种OKULIX光线追踪方法(近轴和2.5 mm瞳孔)。计算预测误差(PE),并使用稳健统计方法(Eyetemis)评估正确度、精密度和准确性。此外还评估了回顾性IOLup1D调整。共纳入149例患者的149只眼。BUII显示出最低的截尾平均绝对误差(0.74 ± 0.65D)和中位绝对误差(0.60D),72%的眼在目标屈光度±1.00D范围内。Olsen光线追踪显示出更高的误差(平均绝对误差1.06 ± 1.02D),而两种OKULIX方法表现相似(0.91-0.92D)。仅OKULIX近轴光线追踪未显示显著的系统性偏倚(p = 0.450),而所有其他公式均显示出显著的远视漂移(p < 0.001)。经过回顾性IOLup1D调整后,BUII和Olsen达到相当的准确性,其中Olsen表现出最高的正确度。与Pentacam相比,IOLMaster测量的平均角膜曲率值陡峭0.20 ± 0.63D。在三联DMEK眼中,基于光线追踪的IOL屈光度计算与BUII相比并未提供更好的准确性。BUII总体上表现出最高的准确性和精密度。经过IOLup1D调整后,BUII和Olsen达到相当的准确性,其中Olsen表现出最高的正确度。
To compare the predictive accuracy of ray tracing-based intraocular lens (IOL) power calculation formulas with the Barrett Universal II (BUII) formula in eyes with Fuchs endothelial corneal dystrophy (FECD) undergoing combined cataract surgery and Descemet membrane endothelial keratoplasty (triple DMEK). This is a retrospective, single-centre comparative case series. Preoperative biometry was obtained using Scheimpflug tomography (Pentacam AXL) and a swept-source optical coherence tomography-based biometer (IOLMaster 700). IOL power calculations were performed using Barrett Universal II (BUII), Olsen ray-tracing and two OKULIX ray-tracing approaches (paraxial and 2.5-mm pupil). Prediction error (PE) was calculated and trueness, precision, and accuracy were evaluated using robust statistical methods (Eyetemis). A retrospective IOLup1D adjustment was additionally assessed. One hundred forty-nine eyes of 149 patients were enrolled. BUII demonstrated the lowest trimmed mean absolute error (0.74 ± 0.65D) and median absolute error (0.60D), with 72% of eyes within ±1.00D of the target refraction. Olsen ray-tracing showed higher errors (mean absolute error 1.06 ± 1.02D), while both OKULIX approaches performed similarly (0.91-0.92D). Only OKULIX paraxial ray-tracing showed no significant systematic bias (p = 0.450), whereas all other formulas demonstrated a significant hyperopic shift (p < 0.001). After retrospective IOLup1D adjustment, BUII and Olsen achieved comparable accuracy, with Olsen demonstrating the highest trueness. Mean keratometry values measured with the IOLMaster were 0.20 ± 0.63D steeper compared to the Pentacam. In triple DMEK eyes, ray tracing-based IOL power calculation did not offer better accuracy compared to BUII. BUII demonstrated the highest accuracy and precision overall. After IOLup1D adjustment, BUII and Olsen achieved comparable accuracy, with Olsen showing the greatest trueness.
Jan O Weber, Klemens P Kaiser, Jascha A Wendelstein, H Burkhard Dick, Thomas Kohnen, Ingo Schmack. Ray-Tracing-Based Intraocular Lens Power Calculation in Combined Cataract Surgery and Descemet Membrane Endothelial Keratoplasty.. Clinical & experimental ophthalmology. 2026; doi:10.1111/ceo.70135.
Jan O Weber, Klemens P Kaiser, Jascha A Wendelstein, H Burkhard Dick, Thomas Kohnen, Ingo Schmack (2026). Ray-Tracing-Based Intraocular Lens Power Calculation in Combined Cataract Surgery and Descemet Membrane Endothelial Keratoplasty.. Clinical & experimental ophthalmology. https://doi.org/10.1111/ceo.70135
Jan O Weber, Klemens P Kaiser, Jascha A Wendelstein, H Burkhard Dick, Thomas Kohnen, Ingo Schmack. Ray-Tracing-Based Intraocular Lens Power Calculation in Combined Cataract Surgery and Descemet Membrane Endothelial Keratoplasty.[J]. Clinical & experimental ophthalmology, 2026 doi:10.1111/ceo.70135.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出