OpenCap的有效性和可靠性:一种低成本的无标记运动捕捉系统,用于股骨头假体用户的下肢运动学
Validity and Reliability of OpenCap: A low-cost markerless motion capture system for lower extremity kinematics in Transfemoral prosthetic users.
Validity and Reliability of OpenCap: A low-cost markerless motion capture system for lower extremity kinematics in Transfemoral prosthetic users.
基于三维标记的光学系统(MBS)是生物力学测量的基准,但受限于成本、时间和可及性。OpenCap是一个基于网络的三维无标记运动捕捉系统,有望解决这些局限,但其在股骨截肢假肢使用者中的有效性和可靠性仍不明确。本研究旨在评估OpenCap在31名股骨截肢假肢使用者(平均年龄44.52 ± 14.90岁)中的有效性和会话内可靠性。参与者在双带跑步机上以自选舒适速度进行步行试验,同时使用OpenCap和MBS采集运动学数据。统计分析包括组内相关系数(ICC)、统计参数映射(SPM1d)和均方根误差(RMSE)。OpenCap在时空参数方面表现出极好的一致性(ICC >0.99,RMSE <2)。然而,各关节运动学参数之间的一致性存在差异,在峰值关节角度估计方面观察到较低的准确性。RMSE值总体范围为0至10°,髋关节旋转的误差较高(>10°)。对于时间序列运动学,SPM1d分析识别出步态周期中关节运动学的显著差异(p < 0.05),尤其是在膝关节和踝关节。时空参数及若干矢状面和额面运动学变量的会话内可靠性为良好至优秀(ICC >0.75)。在双侧横断面测量及假肢侧部分踝关节测量中观察到较低的可靠性(ICC = 0.584-0.733),尤其是假肢侧髋关节旋转活动度。OpenCap可提供有效的时空数据,可作为步态评估的可及工具。然而,关节运动学准确性有待提高。未来研究应侧重于优化复杂假肢运动的追踪。
The 3D marker-based optical system (MBS) is the benchmark for biomechanical measurement, but it is limited by cost, time, and accessibility. OpenCap, a web-based 3D markerless motion capture system, has the potential to address these limitations, although its validity and reliability in transfemoral prosthesis users remain unclear. This study aimed to evaluate the validity and within-session reliability of OpenCap in 31 transfemoral prosthetic users (mean age 44.52 ± 14.90 years). Participants performed walking trials on a dual-belt treadmill at a self-selected comfortable speed, while kinematic data were collected simultaneously using OpenCap and MBS. Statistical analyses included Intraclass Correlation Coefficients (ICC), Statistical Parametric Mapping (SPM1d), and Root Mean Square Error (RMSE). OpenCap showed excellent agreement for spatiotemporal parameters (ICC >0.99 with RMSE <2). However, agreement across joint kinematics varied between parameters, with lower accuracy observed in peak joint angle estimation. RMSE values generally ranged from 0 to 10°, with higher errors observed in hip rotation (>10°). For time-series kinematics, SPM1d analysis identified significant differences (p < 0.05) in joint kinematics across the gait cycle, particularly at the knee and ankle. Within-session reliability was good to excellent (ICC >0.75) for spatiotemporal parameters and several sagittal- and frontal-plane kinematic variables. Lower reliability (ICC = 0.584-0.733) was observed in transverse-plane measures on both sides and in some ankle measures on the prosthetic side, particularly hip rotation ROM on the prosthetic side. OpenCap provides valid spatiotemporal data and may serve as an accessible tool for gait assessment. However, joint kinematic accuracy requires improvement. Future research should focus on optimizing tracking for the complex prosthetic movements.
Wisavaporn Niamsang, Gary Guerra, Worapan Kusakunniran, Harit Apidech, Pattaraporn Kongsatan, Pilipda Chaiwan, et al. Validity and Reliability of OpenCap: A low-cost markerless motion capture system for lower extremity kinematics in Transfemoral prosthetic users.. Computers in biology and medicine. 2026; doi:10.1016/j.compbiomed.2026.111817.
Wisavaporn Niamsang, Gary Guerra, Worapan Kusakunniran, Harit Apidech, Pattaraporn Kongsatan, Pilipda Chaiwan, et al (2026). Validity and Reliability of OpenCap: A low-cost markerless motion capture system for lower extremity kinematics in Transfemoral prosthetic users.. Computers in biology and medicine. https://doi.org/10.1016/j.compbiomed.2026.111817
Wisavaporn Niamsang, Gary Guerra, Worapan Kusakunniran, Harit Apidech, Pattaraporn Kongsatan, Pilipda Chaiwan, et al. Validity and Reliability of OpenCap: A low-cost markerless motion capture system for lower extremity kinematics in Transfemoral prosthetic users.[J]. Computers in biology and medicine, 2026 doi:10.1016/j.compbiomed.2026.111817.