耐用的含氟聚合物药物洗脱支架与裸金属支架在预防颅内支架内再狭窄方面的比较
Durable fluoropolymer drug-eluting stent versus bare-metal stent for the prevention of intracranial in-stent restenosis.
Durable fluoropolymer drug-eluting stent versus bare-metal stent for the prevention of intracranial in-stent restenosis.
与裸金属支架(BMS)相关的高支架内再狭窄(ISR)发生率削弱了血管内治疗作为严重症状性颅内动脉粥样硬化性狭窄(ICAS)患者治疗选择的可行性。本研究旨在评估在严重ICAS治疗中,耐久性含氟聚合物药物洗脱支架(DES)与BMS相比是否能降低ISR的发生率。本前瞻性、多中心、开放标签、结局盲法评价临床试验在中国16个中心开展,纳入因颅内大动脉70%~99%狭窄所致缺血性卒中或短暂性脑缺血发作(<90天)的患者。符合条件的患者被随机分配接受耐久性含氟聚合物DES或BMS进行狭窄治疗。主要结局为术后1年ISR,定义为支架内或紧邻支架处(5 mm以内)发生≥50%的狭窄。次要结局包括症状性ISR以及30天内卒中或死亡或31天至1年靶血管供血区卒中。2023年2月20日至2024年4月10日期间,共纳入156例患者,分配至DES组(n=78)或BMS组(n=78)。中位年龄为61岁(IQR 54~67),156例患者中129例(82.7%)为男性。1年时,DES组主要结局发生率为2.9%,BMS组为27.9%(风险差-0.25,95% CI -0.37~-0.13,p<0.001)。DES组与BMS组在症状性ISR(0% vs 2.9%,p=0.20)以及30天内卒中或死亡或31天至1年靶血管供血区卒中(7.7% vs 12.3%,p=0.45)方面未观察到显著差异。在严重ICAS患者中,与BMS相比,耐久性含氟聚合物DES治疗使1年ISR发生率更低。NCT05719883。
The high incidence of in-stent restenosis (ISR) associated with bare-metal stents (BMS) undermines the viability of endovascular treatment as a treatment option for patients with severe symptomatic intracranial atherosclerotic stenosis (ICAS). The study aimed to evaluate whether durable fluoropolymer drug-eluting stents (DES) reduce the incidence of ISR compared with BMS in the treatment of severe ICAS. This prospective, multicentre, open-label, blinded outcome clinical trial was conducted at 16 centres in China, enrolling patients with ischaemic stroke or transient ischaemic attack (<90 days) attributed to 70%-99% stenosis of an intracranial major artery. Eligible patients were randomly assigned to receive durable fluoropolymer DES or BMS for stenosis treatment. The primary outcome was ISR at 1 year postprocedure, which was defined as a stenosis rate of ≥50% occurring within or immediately adjacent to (within 5 mm) the stent. Secondary outcomes included symptomatic ISR and stroke or death within 30 days or stroke in the target vessel territory between 31 days and 1 year. Between 20 February 2023 and 10 April 2024, 156 patients were enrolled and assigned to receive DES (n=78) or BMS (n=78). The median age was 61 years (IQR 54-67), and 129 (82.7%) of 156 patients were male. At 1 year, the primary outcome occurred in 2.9% in the DES group versus 27.9% in the BMS group (risk difference -0.25, 95% CI -0.37 to -0.13, p<0.001). No significant differences were observed between the DES and BMS groups in symptomatic ISR (0% vs 2.9%, p=0.20) or in stroke or death within 30 days or stroke in the target vessel territory between 31 days and 1 year (7.7% vs 12.3%, p=0.45). Among patients with severe ICAS, treatment with durable fluoropolymer DES resulted in a lower 1-year ISR compared with BMS. NCT05719883.
Ying Yu, Xuan Wang, Liangfu Zhu, Chengbo Dai, Weisheng Deng, Yunfeng Zhang, et al. Durable fluoropolymer drug-eluting stent versus bare-metal stent for the prevention of intracranial in-stent restenosis.. Journal of neurology, neurosurgery, and psychiatry. 2026; doi:10.1136/jnnp-2026-338887.
Ying Yu, Xuan Wang, Liangfu Zhu, Chengbo Dai, Weisheng Deng, Yunfeng Zhang, et al (2026). Durable fluoropolymer drug-eluting stent versus bare-metal stent for the prevention of intracranial in-stent restenosis.. Journal of neurology, neurosurgery, and psychiatry. https://doi.org/10.1136/jnnp-2026-338887
Ying Yu, Xuan Wang, Liangfu Zhu, Chengbo Dai, Weisheng Deng, Yunfeng Zhang, et al. Durable fluoropolymer drug-eluting stent versus bare-metal stent for the prevention of intracranial in-stent restenosis.[J]. Journal of neurology, neurosurgery, and psychiatry, 2026 doi:10.1136/jnnp-2026-338887.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出