再次手术主动脉瓣置换术与带球囊瓣膜断裂的瓣膜内经导管主动脉瓣置换手术:短期临床结果
Redo surgical aortic valve replacement versus valve-in-valve transcatheter aortic valve replacement with balloon valve fracture: Short-term clinical outcomes.
Redo surgical aortic valve replacement versus valve-in-valve transcatheter aortic valve replacement with balloon valve fracture: Short-term clinical outcomes.
评估生物瓣结构性瓣膜毁损患者接受再次外科主动脉瓣置换术(redo-SAVR)与瓣中瓣经导管主动脉瓣置换术联合生物瓣膜断裂术(ViV-TAVR联合ViVBVF)的短期结局。本回顾性单中心研究于2015年至2025年间开展,数据来源于机构登记数据库。共128例连续患者符合纳入标准(75例接受redo-SAVR,53例接受ViVBVF)。需同期行心脏手术、机械瓣或解剖不适合ViV的患者被排除。主要终点为30天死亡率、卒中和再入院;次要终点包括超声心动图变化和术后并发症。采用重叠倾向评分加权以校正基线差异。与redo-SAVR患者相比,ViVBVF患者年龄更大且预测死亡风险更高。两组30天死亡率、卒中和再入院率相似。ViVBVF在平均跨瓣压差(-26.0 mmHg vs -17.4 mmHg;P=0.003)、峰值跨瓣压差(-39.2 mmHg vs -23.3 mmHg;P=0.004)及峰值流速方面均取得显著更大的降低。匹配后,redo-SAVR术后30天死亡率更高(8.9% vs 0%;P<0.001)。ViVBVF组峰值流速降低更明显,但起搏器植入更频繁。在需要再次干预的生物瓣患者中,ViVBVF提供更大的跨瓣压差降低,校正分析提示其围术期安全性更具优势。
To evaluate short-term outcomes of redo surgical aortic valve replacement (SAVR) versus valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) with bioprosthetic valve fracture (ViVBVF) in patients with bioprosthetic structural valve deterioration undergoing reintervention. This retrospective single-center study was conducted between 2015 and 2025. Data were obtained from institutional registries. A total of 128 consecutive patients met the inclusion criteria (75 with redo-SAVR and 53 with ViVBVF). Patients requiring concomitant cardiac procedures, mechanical valves, or unsuitable anatomy for ViV were excluded. The primary endpoints were 30-day mortality, stroke, and readmission; secondary endpoints included echocardiographic changes and postoperative complications. Overlap propensity score weighting to adjust baseline differences was performed. Compared to the redo-SAVR patients, the ViVBVF patients were older and had a higher predicted risk of mortality. The rates of 30-day mortality, stroke, and readmission were similar in the 2 groups. ViVBVF achieved significantly greater reductions in mean gradient (-26.0 mm Hg vs -17.4 mm Hg; .003), peak gradient (-39.2 mm Hg vs -23.3 mm Hg; .004), and peak velocity. After matching, 30-day mortality was higher after redo-SAVR (8.9% vs 0%; < .001). The ViVBVF group showed a greater reduction in peak velocity but more frequent pacemaker implantation. In patients with bioprosthetic valves requiring reintervention, ViVBVF offers greater gradient reduction, with a perioperative safety advantage suggested in the adjusted analysis.
Rahul Kanade, Marco Tagliafierro, Isao Anzai, Fady Soliman, William M Mitchell, Darina Kirilina, et al. Redo surgical aortic valve replacement versus valve-in-valve transcatheter aortic valve replacement with balloon valve fracture: Short-term clinical outcomes.. JTCVS structural and endovascular. 2026; doi:10.1016/j.xjse.2026.100127.
Rahul Kanade, Marco Tagliafierro, Isao Anzai, Fady Soliman, William M Mitchell, Darina Kirilina, et al (2026). Redo surgical aortic valve replacement versus valve-in-valve transcatheter aortic valve replacement with balloon valve fracture: Short-term clinical outcomes.. JTCVS structural and endovascular. https://doi.org/10.1016/j.xjse.2026.100127
Rahul Kanade, Marco Tagliafierro, Isao Anzai, Fady Soliman, William M Mitchell, Darina Kirilina, et al. Redo surgical aortic valve replacement versus valve-in-valve transcatheter aortic valve replacement with balloon valve fracture: Short-term clinical outcomes.[J]. JTCVS structural and endovascular, 2026 doi:10.1016/j.xjse.2026.100127.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出