成人脊柱畸形手术中,新型埃菲尔铁塔结构与传统骨盆固定的腰椎、骶髂螺钉应变的生物力学比较
Biomechanical Comparison of Lumbar, Sacral and Iliac Screw Strain with the Novel Eiffel Tower Configuration Versus Conventional Pelvic Fixation in Adult Spinal Deformity Surgery.
Biomechanical Comparison of Lumbar, Sacral and Iliac Screw Strain with the Novel Eiffel Tower Configuration Versus Conventional Pelvic Fixation in Adult Spinal Deformity Surgery.
长节段脊柱融合术中常见的问题是尾端固定失败。为解决骶骨螺钉松动问题,可将固定延伸至骨盆并使用髂骨螺钉。髂骨螺钉提供较强的锚定强度,但由于应变较高,松动较为常见。一种新型的“埃菲尔铁塔”(Eiffel Tower,E-T)构造被引入以降低髂骨螺钉应变。在锯骨脊柱模型上,使用椎弓根螺钉和棒从T9至S1进行原生固定。在屈曲、伸展、侧弯和旋转方向上施加25Nm载荷时,测量L5和S1螺钉的应变。固定延伸至骨盆后,测量L5、S1和髂骨螺钉的应变。传统模型使用连接内侧髂嵴螺钉与L5上方主棒的桥接结构。E-T固定使用两根棒,在L1处与主棒连接,并连接至髂嵴上外侧的两枚螺钉。传统固定使S1应变降低65%,E-T固定降低77%。在所有加载方向上,E-T固定相比传统固定对S1螺钉应变的降低幅度更大。在所有加载方向上,E-T固定相比传统固定使髂骨螺钉应变降低。传统固定相比原生固定增加了L5螺钉应变,而E-T固定则没有。传统固定和E-T固定均能降低S1螺钉应变,但E-T固定的降低程度更大。相对于E-T固定,传统固定在髂骨螺钉处的终端固定承受了更高的载荷。(Journal of Surgical Orthopaedic Advances 35(2):072-076, 2026)。
A common problem in long spinal fusions is caudal end fixation failure. To address sacral screw loosening, fixation may be extended to the pelvis using iliac screws. Iliac screws provide strong anchor strength, but loosening is common due to high strain. A novel 'Eiffel Tower' (E-T) construct is introduced to reduce iliac screw strain. A saw-bone spine model was instrumented with pedicle screws and rods from T9 to S1 as native fixation. L5 and S1 screw strain was measured with application of 25Nm loading in flexion, extension, lateral bending and rotation. Strain was measured for L5, S1 and iliac screws after fixation was extended to the pelvis. The conventional model used a bridge connecting a screw in the medial iliac crest to the main rod superior to L5. The E-T fixation used two rods connected to the main rods at L1 and to two screws in the superolateral iliac crest. S1 strain is reduced by 65% by conventional fixation and 77% by E-T fixation. S1 screw strain reduction was greater with E-T fixation compared to conventional fixation in all loading directions. Iliac screw strain was decreased with E-T fixation compared to conventional fixation in all loading directions. Conventional fixation increased L5 screw strain compared to native fixation, but E-T fixation did not. Both conventional and E-T fixation reduce S1 screw strain, but E-T fixation did so to a greater extent. Terminal fixation at the iliac screw suffered a higher load with conventional fixation relative to E-T fixation. (Journal of Surgical Orthopaedic Advances 35(2):072-076, 2026).
Alex Ha, Alex Yerukhimov, Jisoo Kim, Dilip Sengupta. Biomechanical Comparison of Lumbar, Sacral and Iliac Screw Strain with the Novel Eiffel Tower Configuration Versus Conventional Pelvic Fixation in Adult Spinal Deformity Surgery.. Journal of surgical orthopaedic advances. 2026;
Alex Ha, Alex Yerukhimov, Jisoo Kim, Dilip Sengupta (2026). Biomechanical Comparison of Lumbar, Sacral and Iliac Screw Strain with the Novel Eiffel Tower Configuration Versus Conventional Pelvic Fixation in Adult Spinal Deformity Surgery.. Journal of surgical orthopaedic advances.
Alex Ha, Alex Yerukhimov, Jisoo Kim, Dilip Sengupta. Biomechanical Comparison of Lumbar, Sacral and Iliac Screw Strain with the Novel Eiffel Tower Configuration Versus Conventional Pelvic Fixation in Adult Spinal Deformity Surgery.[J]. Journal of surgical orthopaedic advances, 2026
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出