通用脑电图夹减少了脑电图中的头发纹理偏差

The Universal Electroencephalography Clip reduces hair-texture bias in electroencephalography.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

标准脑电图(EEG)电极帽设计用于快速、一致地放置电极,但与卷曲至紧密卷曲的发质不相容,因为电极无法可靠地接触到头皮。这对特定族裔群体造成了不成比例的影响。我们开发了通用脑电图夹(UE-C),可在不要求编发程序的情况下跨发质和发型进行数据采集。我们测试了听觉和视觉反应,以评估各头皮区域的信号质量。57名参与者(37名直发至波浪发;20名卷曲至紧密卷曲发)在佩戴UE-C和EEG帽进行脑电图记录时,听取了4 Hz的听觉咔嗒声并观看了4/6 Hz的对比度反转光栅。使用方差分析和信号增益百分比比较了各方法在伪迹剔除后的 epoch 保留率和信噪比(SNR)。相对于电极帽,UE-C在视觉区域(卷曲至紧密卷曲发+10%;直发至波浪发+12%)和听觉区域(卷曲至紧密卷曲发+8%;直发至波浪发-8%)均保留了更多 epoch。视觉4-Hz SNR在直发至波浪发组中增强(p = 0.01),在卷曲至紧密卷曲发组中未增强(p = 0.06)。视觉位点的SNR有所改善(信号增益:卷曲至紧密卷曲发+34%;直发至波浪发+30%)。在听觉位点观察到可忽略不计的影响,该处电极至头皮问题较不可能发生。在视觉电极处,UE-C比电极帽保留了更多数据且信号质量改善,无论发质如何。听觉位点数据在两种方法之间相当。UE-C的表现与SEVO夹相似,无需编发要求且适应各种发型。我们展示了电极至头皮问题的另一个实例,并分享了有助于纠正脑电图方法学中头发偏倚的研究发现。

Abstract

Standard electroencephalography (EEG) electrode caps, designed for fast and consistent placement, are incompatible with curly-to-coiled hair textures because electrodes cannot reliably reach the scalp. This disproportionately affects specific ethnic groups. We developed the Universal Electroencephalography Clip (UE-C) for data collection across hair types and styles without requiring braiding procedures. We tested auditory and visual responses to assess signal quality across scalp regions. 57 participants (37 straight-to-wavy; 20 curly-to-coiled hair) heard auditory clicks at 4 Hz and viewed contrast-reversing gratings at 4/6Hz during EEG recording with the UE-C and the EEG cap. Epoch retention after artifact rejection and Signal-to-Noise Ratios (SNR) were compared across methods using ANOVAs and percent signal gain. The UE-C retained more epochs at both visual (+10% curly-to-coiled; +12% straight-to-wavy) and auditory regions (+8% curly-to-coiled; -8% straight-to-wavy) relative to the cap. Visual 4-Hz SNR was enhanced (p = 0.01) with straight-to-wavy, not curly-to-coiled (p = 0.06). SNRs improved at visual sites (signal gain: +34%; curly-to-coiled; +30% straight to wavy). Negligible effects were observed at the auditory site, where the electrode-to-scalp problem is less likely. At the visual electrode, the UE-C retained more data with improved signal quality over the cap, despite hair texture. Auditory-site data were comparable between methods. The UE-C performed similarly to the SEVO clip, without braiding requirements and accommodating various hairstyles. We demonstrated another example of the electrode-to-scalp problem and share findings that offer a step forward toward correcting the hair bias in EEG methodology.

如何引用

AMA

Wendy A Torrens, Skylor Olshefsky, Rasia B Yankaway, Michelle Ruiz, Kensal G Coudriet, Mia K Price, et al. The Universal Electroencephalography Clip reduces hair-texture bias in electroencephalography.. Neuroscience. 2026; doi:10.1016/j.neuroscience.2026.05.041.

APA

Wendy A Torrens, Skylor Olshefsky, Rasia B Yankaway, Michelle Ruiz, Kensal G Coudriet, Mia K Price, et al (2026). The Universal Electroencephalography Clip reduces hair-texture bias in electroencephalography.. Neuroscience. https://doi.org/10.1016/j.neuroscience.2026.05.041

GB/T 7714

Wendy A Torrens, Skylor Olshefsky, Rasia B Yankaway, Michelle Ruiz, Kensal G Coudriet, Mia K Price, et al. The Universal Electroencephalography Clip reduces hair-texture bias in electroencephalography.[J]. Neuroscience, 2026 doi:10.1016/j.neuroscience.2026.05.041.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Neuroscience 的其他文献