长通滤光片对近视离焦引起的眼轴长度和脉络膜厚度变化的影响
Effect of a longpass filter on myopic defocus-induced changes in axial length and choroid thickness.
Effect of a longpass filter on myopic defocus-induced changes in axial length and choroid thickness.
探讨长波通滤光片对近视性离焦诱导的眼轴长度(AL)和脉络膜厚度(ChT)短期变化的影响。本研究纳入23名年轻近视成人。在右眼通过长波通滤光片(>495 nm)或同等透射率的中性密度(ND)滤光片诱导+5 D近视性离焦60分钟前后,测量双眼的AL和ChT。左眼及对照眼均使用相同的ND滤光片。在每次测试前及测试后10分钟测量左眼瞳孔直径。照明维持在100勒克斯。使用ND滤光片进行单眼离焦60分钟后,右眼AL显著缩短(均值±标准误)(-8.20 ± 3.01 μm;t = -2.72;P = 0.01)。然而,ChT未见显著变化(-0.73 ± 1.78 μm;t = -0.41;P = 0.69)。使用长波通滤光片时,AL未见显著变化(-1.11 ± 4.27 μm,t = -0.26,P = 0.80),但ChT显著降低(-4.56 ± 1.73 μm,t = -2.63,P = 0.02)。两种滤光片之间的瞳孔大小无显著差异(F = 0.004,P = 0.95)。阻断短波长抑制了近视性离焦引起的急性眼轴缩短反应,提示在当前实验条件下短波长在屈光发育中具有调节作用。
To investigate the short-term effect of a longpass filter on myopic defocus-induced changes in axial length (AL) and choroidal thickness (ChT). This study included 23 young myopic adults. AL and ChT were measured in both eyes before and after 60 min of +5 D myopic defocus induced in the right eye with either a longpass filter (>495 nm) or a neutral density (ND) filter of equal transmittance. The same ND filter was used for both the left eye and the control eye. The pupil diameter of the left eye was measured before and 10 min after each test session. Illumination was maintained at 100 lux. After 60 min of monocular defocusing with the ND filter, a significant reduction in AL (mean±SE) was observed in the right eye (-8.20 ± 3.01 μm; = -2.72; = 0.01). However, no significant change was noted in ChT (-0.73 ± 1.78 μm; = -0.41; = 0.69). With the longpass filter, no significant change in AL was observed (-1.11 ± 4.27 μm, t = -0.26, = 0.80), but a significant reduction in ChT was observed (-4.56 ± 1.73 μm, = -2.63, = 0.02). Pupil size did not significantly differ between the two filters ( = 0.004, = 0.95). Blocking short wavelengths inhibited the acute axial shortening response to myopic defocus, suggesting a modulatory role of short wavelengths in refractive development under the present experimental conditions.
Xue Li, Chenyao Liu, Weilin Wu, Daniel P Spiegel, Björn Drobe, Hao Chen, et al. Effect of a longpass filter on myopic defocus-induced changes in axial length and choroid thickness.. Frontiers in neuroscience. 2026; doi:10.3389/fnins.2026.1783536.
Xue Li, Chenyao Liu, Weilin Wu, Daniel P Spiegel, Björn Drobe, Hao Chen, et al (2026). Effect of a longpass filter on myopic defocus-induced changes in axial length and choroid thickness.. Frontiers in neuroscience. https://doi.org/10.3389/fnins.2026.1783536
Xue Li, Chenyao Liu, Weilin Wu, Daniel P Spiegel, Björn Drobe, Hao Chen, et al. Effect of a longpass filter on myopic defocus-induced changes in axial length and choroid thickness.[J]. Frontiers in neuroscience, 2026 doi:10.3389/fnins.2026.1783536.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出