AIIR算法在儿童腹部增强CT图像质量改善和降噪中的应用

Application of AIIR algorithm for quality improvement and noise reduction in pediatric abdominal contrast-enhanced CT.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

探讨深度学习全模型迭代算法(AIIR)在儿童增强全腹部CT扫描中降低辐射剂量的可行性与价值。回顾性收集100例因临床指征行增强全腹部CT扫描的患儿资料,分为常规组(50例,100 kVp,自动电流调制100 mAs,采用混合迭代重建(HIR))和实验组(50例,80 kVp,自动电流调制180 mAs,采用HIR及AIIR重建)。比较动脉期三组的主观图像质量评分(五分法评估)、主要器官的信噪比(SNR)和对比噪声比(CNR)、对比剂用量及辐射剂量(CTDIvol、DLP、ED)。实验组辐射剂量显著低于常规组(ED降低23.61%,P<0.001)。图像质量方面,主观评分显示AIIR组优于常规HIR组和实验HIR组(P<0.05),医师间一致性极好(Kappa>0.70)。AIIR组肝脏、脾脏、肾脏、胆囊、胰腺及腹主动脉的SNR和CNR值均显著高于HIR组(均P<0.05)。AIIR算法在低剂量水平(80 kVp)下获得的图像质量优于常规HIR和低剂量HIR方案,在儿童腹部成像中具有显著的临床价值和广泛应用潜力。

Abstract

To investigate the feasibility and value of the deep learning full model iterative algorithm (AIIR) in reducing radiation dose during contrast-enhanced whole abdominal CT scans in children. Data from 100 pediatric patients undergoing contrast-enhanced whole abdominal CT scans due to clinical indications were retrospectively collected. The patients were divided into a conventional group ( = 50,100 kVp, automatic current modulation 100 mAs) using hybrid iterative reconstruction (HIR) and an experimental group ( = 50,80 kVp, automatic current modulation 180 mAs) employing HIR and AIIR reconstruction. Subjective image quality scores (five-point scale evaluation), signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of major organs, contrast agent dosage, and radiation dose (CTDIvol, DLP, ED) were compared among the three groups during the arterial phase. The experimental group exhibited significantly lower radiation dose compared to the conventional group (ED reduction by 23.61%, < 0.001). In terms of image quality, subjective scores indicated superior performance of the AIIR group over both conventional HIR and experimental HIR groups ( < 0.05), with excellent inter-physician agreement (Kappa>0.70). The AIIR group demonstrated significantly higher SNR and CNR values for the liver, spleen, kidneys, gallbladder, pancreas, and abdominal aorta compared to the HIR groups (all < 0.05). The AIIR algorithm achieves superior image quality at low dose levels (80 kVp) compared to conventional HIR and low-dose HIR protocols, demonstrating significant clinical value and potential for widespread application in pediatric abdominal imaging.

如何引用

AMA

Xie Jiazhi, Dai Dajian, Tang Shilong, Fan Xiao, Zhu Luyao, He Ling. Application of AIIR algorithm for quality improvement and noise reduction in pediatric abdominal contrast-enhanced CT.. Frontiers in radiology. 2026; doi:10.3389/fradi.2026.1803622.

APA

Xie Jiazhi, Dai Dajian, Tang Shilong, Fan Xiao, Zhu Luyao, He Ling (2026). Application of AIIR algorithm for quality improvement and noise reduction in pediatric abdominal contrast-enhanced CT.. Frontiers in radiology. https://doi.org/10.3389/fradi.2026.1803622

GB/T 7714

Xie Jiazhi, Dai Dajian, Tang Shilong, Fan Xiao, Zhu Luyao, He Ling. Application of AIIR algorithm for quality improvement and noise reduction in pediatric abdominal contrast-enhanced CT.[J]. Frontiers in radiology, 2026 doi:10.3389/fradi.2026.1803622.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Frontiers in radiology 的其他文献