“救援螺钉”作为植入物松动的徒手翻修策略:技术说明及人体尸体比较生物力学研究
The "Rescue screw" as a freehand revision strategy for implant loosening: a technical note and comparative biomechanical study on human cadavers.
The "Rescue screw" as a freehand revision strategy for implant loosening: a technical note and comparative biomechanical study on human cadavers.
根据骨密度不同,脊柱内固定术后植入物松动发生率高达54%。这会导致愈合受损、不稳定和机械性疼痛,常需手术翻修。翻修策略在很大程度上取决于椎弓根内残留骨量,包括使用更大直径或双螺距螺钉、植入物骨水泥强化、替代螺钉轨迹如皮质骨轨迹(CBT)、打压植骨以及延伸至完整邻近节段。本研究通过生物力学方法比较直径大2 mm的螺钉(LD)、CBT螺钉和头尾向“补救螺钉”(RS)在已松动的骨水泥强化和原生索引椎弓根螺钉背景下的表现。人体尸体生物力学研究。解剖5具人体尸体腰椎的椎体。经过随机化和使用大1 mm的攻丝模拟螺钉松动后,每种测试轨迹在所有腰椎节段上以交替顺序进行测试。RS和LD螺钉分别针对骨水泥强化和非骨水泥索引椎弓根螺钉进行分析。对侧相应椎弓根植入传统椎弓根螺钉作为样本内参照。在生物力学测试机上记录所有螺钉在屈曲状态下的最大弯曲失效载荷[Nm]。总体而言,翻修螺钉的最大扭矩(34.0 Nm)显著高于对照(27 Nm)(+25.9%;p=.006)。在原生索引螺钉中,LD螺钉显示出最高的中位扭矩(35.3 Nm;+19.5%)。补救螺钉相较于对侧对照扭矩增加11.6%(32.1 Nm)。在骨水泥强化索引螺钉中,LD螺钉(45.1 Nm,+59.2%)和补救螺钉(48.9 Nm;+41%)的这一效应更为显著。在既往螺钉松动的背景下,CBT螺钉未能恢复索引螺钉的机械强度(29.4 Nm;-2.7%)。在此尸体螺钉松动模型中,对于骨水泥强化和原生索引椎弓根螺钉,LD螺钉的机械性能最佳,补救椎弓根螺钉次之。CBT螺钉在椎弓根螺钉松动的情况下不适用。鉴于翻修手术数量不断增加,当因显著骨丢失而无法使用更大直径螺钉时,补救椎弓根螺钉提供了一种生物力学稳健且技术简单的翻修策略,可使用标准植入物和基础设施。
Depending on bone mineral density, implant loosening occurs in up to 54% of cases after spinal instrumentation. This leads to compromised healing, instability and mechanical pain, often requiring surgical revision. Revision strategies strongly depend on the remaining bone stock within the pedicle and include the use of larger diameter or dual pitch screws, implant cementation, alternative screw trajectories such as the cortical bone trajectory (CBT), impaction grafting, and extension to the intact adjacent segment. This study biomechanically compares screws with a 2 mm larger diameter (LD), CBT screws, and craniocaudal "rescue screws" (RS) in the setting of loosened cemented and native index pedicle screws. Biomechanical study on human cadavers. The vertebral bodies of 5 human cadaveric lumbar spines were dissected. After randomization and simulated screw loosening with a 1 mm larger tapping, each test trajectory was tested in alternating order on all lumbar levels. RS and LD screws were analyzed for cemented and uncemented index pedicle screws. The respective contralateral pedicle was instrumented with a conventional pedicle screw as an intrasample reference. Maximum bending load-to-failure [Nm] in flexion was recorded for all screws in a biomechanic testing machine. In total, revision screws showed a significantly higher (+25.9%; p=.006) maximum torque (34.0 Nm) than controls (27 Nm). In native index screws, LD screws showed the highest median torque (35.3 Nm; +19.5%). Rescue screws showed an 11.6% torque increase (32.1 Nm) compared to contralateral controls. In cemented index screws, this effect was even greater for both LD (45.1 Nm, +59.2%) and rescue screws (48.9 Nm; +41%). CBT screws did not restore the mechanical strength of the index screw in the context of prior screw loosening (29.4 Nm; -2.7%). Followed by rescue pedicle screws, LD screws showed the best mechanical performance in this cadaveric screw loosening model for cemented and native index pedicle screws. CBT screws are not useful in the context of pedicle screw loosening. In light of the increasing number of revision surgeries, the rescue pedicle screw offers a biomechanically robust and technically simple revision strategy using standard implants and infrastructure if larger diameter screws are no longer applicable due to significant bone loss.
Mazda Farshad, Aron Alakmeh, Ramon Rohner, Mauro Suter, Florian Wanivenhaus, Jonas Widmer, et al. The "Rescue screw" as a freehand revision strategy for implant loosening: a technical note and comparative biomechanical study on human cadavers.. The spine journal : official journal of the North American Spine Society. 2026; doi:10.1016/j.spinee.2026.05.005.
Mazda Farshad, Aron Alakmeh, Ramon Rohner, Mauro Suter, Florian Wanivenhaus, Jonas Widmer, et al (2026). The "Rescue screw" as a freehand revision strategy for implant loosening: a technical note and comparative biomechanical study on human cadavers.. The spine journal : official journal of the North American Spine Society. https://doi.org/10.1016/j.spinee.2026.05.005
Mazda Farshad, Aron Alakmeh, Ramon Rohner, Mauro Suter, Florian Wanivenhaus, Jonas Widmer, et al. The "Rescue screw" as a freehand revision strategy for implant loosening: a technical note and comparative biomechanical study on human cadavers.[J]. The spine journal : official journal of the North American Spine Society, 2026 doi:10.1016/j.spinee.2026.05.005.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出