用于模拟不稳定桡骨远端骨折闭合复位和经皮穿针的3D打印模型的评估

Evaluation of a 3D-Printed Model for Simulating Closed Reduction and Percutaneous Pinning of Unstable Distal Radius Fractures.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

我们评估了一种用于闭合复位经皮穿针(CRPP)的3D打印移位、不稳定型桡骨远端骨折(DRF)模型的结构效度。我们假设临床DRF经验水平与模型CRPP过程中的操作指标相关。共有13名具有不同DRF经验的志愿者参与,包括骨科住院医师和手外科专科医师(专科培训医师和主治医师)。参与者完成了一项评估DRF CRPP信心和经验的问卷调查;观看了一段演示模型CRPP及评估流程的视频;独立使用单根动力驱动克氏针完成模型CRPP;并对模型提供匿名反馈。一名独立观察者记录了每名参与者的克氏针位置、透视下DRF模型最终矢状面倾斜度数、透视图像数量及操作时间。我们根据经验水平对参与者进行分组分析。第1组由6名非专科骨科住院医师组成,第2组由7名手外科专科医师组成(5名专科培训医师;2名主治医师)。第1组基线信心较低,既往DRF CRPP操作次数较少。第2组在所有指标上均明显优于第1组,包括克氏针进针点和最终轨迹;最终矢状面倾斜度(背侧7° vs. 20°,P < 0.05);透视图像数量(19 vs. 43,P < 0.05);以及操作时间(2:37 vs. 6:01,P < 0.05)。所有参与者均推荐该模型用于教学。在使用我们的移位、不稳定型DRF模型进行CRPP时,手外科主治医师和专科培训医师在所有指标上均优于住院医师,表明该模型具有适当的结构效度。所有参与者均推荐该模型用于操作教学。

Abstract

We evaluated construct validity of a 3D-printed displaced, unstable distal radius fracture (DRF) model for closed reduction and percutaneous pinning (CRPP). We hypothesized that clinical DRF experience levels would correlate with performance metrics during model CRPP. Thirteen volunteers across a spectrum of DRF experience participated, including orthopaedic surgery residents and hand surgery specialists (fellows and attendings). Participants completed a survey assessing confidence and experience with DRF CRPP; watched a video demonstrating model CRPP and evaluation procedures; independently performed model CRPP with a single, power-driven Kirschner wire; and provided anonymous feedback on the model. An independent observer recorded each participant's Kirschner wire locations, degrees of final sagittal-plane DRF model tilt on fluoroscopy, number of fluoroscopic images, and procedural time. We grouped participants based on experience level for analyses. Group 1 consisted of six nonspecialized orthopaedic surgery residents and group 2 consisted of seven hand surgery specialists (five fellows; two attendings). Group 1 had less baseline confidence and fewer prior DRF CRPPs. Group 2 performed markedly better than group 1 in all metrics, including Kirschner wire entry point and final trajectory; final sagittal plane tilt (7° vs. 20° dorsal, P < 0.05); number of fluoroscopic images (19 vs. 43, P < 0.05); and procedure time (2:37 vs. 6:01, P < 0.05). All participants recommended the model for educational use. Hand surgery attendings and fellows performed better than residents in all metrics for CRPP with our displaced, unstable DRF model, indicating appropriate construct validity. All participants recommended the model for procedural education.

如何引用

AMA

Brian T Sullivan, Nicole D Lee, Gabriel Yohe, Aviram M Giladi, Kenneth R Means. Evaluation of a 3D-Printed Model for Simulating Closed Reduction and Percutaneous Pinning of Unstable Distal Radius Fractures.. Journal of the American Academy of Orthopaedic Surgeons. Global research & reviews. 2026; doi:10.5435/JAAOSGlobal-D-26-00146.

APA

Brian T Sullivan, Nicole D Lee, Gabriel Yohe, Aviram M Giladi, Kenneth R Means (2026). Evaluation of a 3D-Printed Model for Simulating Closed Reduction and Percutaneous Pinning of Unstable Distal Radius Fractures.. Journal of the American Academy of Orthopaedic Surgeons. Global research & reviews. https://doi.org/10.5435/JAAOSGlobal-D-26-00146

GB/T 7714

Brian T Sullivan, Nicole D Lee, Gabriel Yohe, Aviram M Giladi, Kenneth R Means. Evaluation of a 3D-Printed Model for Simulating Closed Reduction and Percutaneous Pinning of Unstable Distal Radius Fractures.[J]. Journal of the American Academy of Orthopaedic Surgeons. Global research & reviews, 2026 doi:10.5435/JAAOSGlobal-D-26-00146.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI