基于不同材料的两种隐形矫治器系统治疗第一前磨牙拔除病例中的三维冠根移动:一项回顾性队列研究
Three-dimensional crown-root movement in first premolar extraction cases treated with two clear aligner systems based on different materials: a retrospective cohort study.
Three-dimensional crown-root movement in first premolar extraction cases treated with two clear aligner systems based on different materials: a retrospective cohort study.
基于三维冠根配准方法,量化并比较两种采用不同材料的隐形矫治系统——SmartTrack(ST)与MasterControl S(MCS)——在拔除第一前磨牙病例中产生的牙冠与牙根移动的三维(3D)偏差。本回顾性队列研究纳入29例患者(58个牙侧),分别接受ST(n=15)或MCS(n=14)治疗。将治疗前(T0)CBCT图像与T0及治疗后(T1)口内扫描进行整合,并以腭皱襞作为参考结构进行重叠配准。采用线性混合效应模型(LMM)估计材料间差异,同时校正年龄、性别及标准化计划移动量。估计值以95%置信区间(CI)报告。两种系统在上颌中切牙(U1)矢状向牙冠内收偏差方面差异无统计学意义(ST:1.25(1.30)mm;MCS:2.13(1.82)mm;LMM差值:-0.81 mm;95% CI -1.89~0.28;P=0.145)。MCS在第二前磨牙(U5)(差值:1.07 mm;95% CI 0.21~1.93;P=0.015)和第一磨牙(U6)(差值:1.04 mm;95% CI 0.13~1.94;P=0.025)的矢状向牙根定位方面偏差较小。ST对U5轴向倾斜度(差值:3.33°;95% CI 0.27~6.39;P=0.033)和转矩(差值:3.04°;95% CI 0.08~6.00;P=0.044)的控制更佳。两种系统均表现出一致的“过山车效应”,在非计划性U1伸长方面差异无统计学意义(差值:0.14 mm;95% CI -0.73~1.02;P=0.747)。隐形矫治系统的生物力学性能似乎因牙齿位置和移动向量而异。SmartTrack对前磨牙角度和转矩的控制更好,而MasterControl S在矢状向牙根位置方面与计划的吻合度更高。
To quantify and compare the three-dimensional (3D) deviations of crown and root movements produced by two clear aligner systems based on different materials-SmartTrack (ST) and MasterControl S (MCS)-in first premolar extraction cases using a 3D crown-root registration approach. This retrospective cohort study included 29 patients (58 dental sides) treated with ST (n = 15) or MCS (n = 14). Pretreatment (T0) CBCT images were integrated with T0 and post-treatment (T1) intraoral scans and superimposed using palatal rugae as reference structures. Linear mixed-effects models (LMM) were applied to estimate between-material differences while adjusting for age, sex, and standardized planned movement magnitude. Estimates are reported with 95% confidence intervals (CI). The two systems demonstrated no statistically significant difference in deviation in sagittal crown retraction of the maxillary central incisor (U1) (ST: 1.25 (1.30) mm; MCS: 2.13 (1.82) mm; LMM difference: - 0.81 mm; 95% CI - 1.89-0.28; P = 0.145). MCS demonstrated smaller deviation in sagittal root positioning for the second premolar (U5) (difference: 1.07 mm; 95% CI 0.21-1.93; P = 0.015) and first molar (U6) (difference: 1.04 mm; 95% CI 0.13-1.94; P = 0.025). ST showed improved control of U5 axial inclination (difference: 3.33°; 95% CI 0.27-6.39; P = 0.033) and torque (difference: 3.04°; 95% CI 0.08 to 6.00; P = 0.044). Both systems exhibited a consistent "roller-coaster effect", with no significant difference in unplanned U1 extrusion (difference: 0.14 mm; 95% CI - 0.73-1.02; P = 0.747). The biomechanical performance of clear aligner systems appears to vary depending on tooth position and movement vector. SmartTrack demonstrated better control of premolar angulation and torque, whereas MasterControl S showed closer agreement with the planned sagittal root position.
Luyao Qu, Runzhe Fang, Ruomei Li, Zitong Yang, Yixin Li, Xuehui Chen, et al. Three-dimensional crown-root movement in first premolar extraction cases treated with two clear aligner systems based on different materials: a retrospective cohort study.. Progress in orthodontics. 2026; doi:10.1186/s40510-026-00624-3.
Luyao Qu, Runzhe Fang, Ruomei Li, Zitong Yang, Yixin Li, Xuehui Chen, et al (2026). Three-dimensional crown-root movement in first premolar extraction cases treated with two clear aligner systems based on different materials: a retrospective cohort study.. Progress in orthodontics. https://doi.org/10.1186/s40510-026-00624-3
Luyao Qu, Runzhe Fang, Ruomei Li, Zitong Yang, Yixin Li, Xuehui Chen, et al. Three-dimensional crown-root movement in first premolar extraction cases treated with two clear aligner systems based on different materials: a retrospective cohort study.[J]. Progress in orthodontics, 2026 doi:10.1186/s40510-026-00624-3.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出