适配体偶联液滴CRISPR/Cas12a实现超灵敏sPD-L1检测

Aptamer-Coupled Droplet CRISPR/Cas12a Enables Ultrasensitive sPD-L1 Detection.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

外周血中可溶性程序性死亡配体1(sPD-L1)的超灵敏检测对于癌症早期诊断和免疫治疗监测至关重要。传统酶联免疫吸附试验缺乏所需的灵敏度,而PCR定量的是核酸替代物而非具有免疫活性的蛋白质。在此,我们报道了一种适配体偶联液滴CRISPR/Cas12a(ADC)平台,该平台将结构切换适配体与皮升液滴微流控技术相结合,可在70分钟内实现sPD-L1的飞摩尔级定量。靶标与适配体结合后置换出阻断序列,从而激活Cas12a的反式切割活性,无需预扩增即可产生荧光液滴。皮升液滴中的空间限制通过提高局部试剂浓度加速反应动力学并抑制背景荧光,从而协同增强灵敏度。该检测对sPD-L1的检出限为0.5 pM,动态范围跨越3个数量级,在肺癌患者和健康供者的盲法血浆样本中实现了100%的诊断准确率。该模块化ADC架构可轻松适配其他蛋白质生物标志物,为快速、超灵敏的液体活检分析提供了通用策略。

Abstract

Ultrasensitive detection of soluble programmed death-ligand 1 (sPD-L1) in peripheral blood is essential for early cancer diagnosis and immunotherapy monitoring. Conventional enzyme-linked immunosorbent assays lack the requisite sensitivity, whereas PCR quantifies nucleic-acid surrogates rather than the immunologically active protein. Here we report an aptamer-coupled droplet CRISPR/Cas12a (ADC) platform that integrates a structure-switching aptamer with picolitre droplet microfluidics to achieve femtomolar quantification of sPD-L1 within 70 min. Target binding with aptamer displaces a blocking sequence that activates Cas12a trans-cleavage, generating fluorescent droplets without preamplification. Confinement in picolitre droplets accelerates reaction kinetics through elevated local reagent concentrations and suppresses background fluorescence, collectively enhancing sensitivity. The assay exhibits a 0.5 pM limit of detection for sPD-L1, a dynamic range spanning 3 orders of magnitude, and 100% diagnostic accuracy in blinded plasma from lung cancer patients and healthy donors. The modular ADC architecture is readily adaptable to other protein biomarkers, offering a universal strategy for rapid, ultrasensitive liquid-biopsy analysis.

如何引用

AMA

Yunping Wu, Ruigang Jin, Ting Lei, Jinnan Liu, Yangyang Chang, Zijie Zhang, et al. Aptamer-Coupled Droplet CRISPR/Cas12a Enables Ultrasensitive sPD-L1 Detection.. Analytical chemistry. 2026; doi:10.1021/acs.analchem.6c00779.

APA

Yunping Wu, Ruigang Jin, Ting Lei, Jinnan Liu, Yangyang Chang, Zijie Zhang, et al (2026). Aptamer-Coupled Droplet CRISPR/Cas12a Enables Ultrasensitive sPD-L1 Detection.. Analytical chemistry. https://doi.org/10.1021/acs.analchem.6c00779

GB/T 7714

Yunping Wu, Ruigang Jin, Ting Lei, Jinnan Liu, Yangyang Chang, Zijie Zhang, et al. Aptamer-Coupled Droplet CRISPR/Cas12a Enables Ultrasensitive sPD-L1 Detection.[J]. Analytical chemistry, 2026 doi:10.1021/acs.analchem.6c00779.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Analytical chemistry 的其他文献