Evaluation of imaging protocols for detecting tooth ankylosis using different CBCT devices: an in vitro study.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

比较不同成像协议采集的CBCT图像检测牙骨粘连的诊断准确性。制备30颗离体恒牙(20颗单根牙,10颗三根牙);通过选择性去除先前涂覆以模拟牙周膜的牙根上的特氟龙,在20颗牙齿中模拟骨粘连。将样本包埋于人造石石膏中,并使用2台CBCT设备上的4种协议进行成像。CBCT图像主要由一名设盲的放射科医师进行评估(存在/不存在)。对20%的标本进行微CT以验证模型。计算一致性和准确性指标(Fleiss/Cohen κ、灵敏度、特异度、阳性预测值、阴性预测值)。协议2(0.25 mm体素)表现出最佳性能(κ = 0.113;灵敏度71.4%;阳性预测值52.6%;阴性预测值60%)。协议3(0.35 mm体素)表现最差(κ = -0.104;灵敏度53.8%;阳性预测值43.8%;阴性预测值45.5%)。除协议3外,灵敏度较高(≥71.4%),而特异度仍然较低(35.7%-42.9%)。本研究有其自身局限性。临床实践中用于检测骨粘连的不同成像协议也可加以研究,以提供评估骨粘连的不同方法。CBCT在骨粘连检测中表现出高灵敏度但低特异度,提示存在假阳性倾向。较小的体素尺寸(0.25-0.30 mm)改善了检测效果,而0.35 mm最不可靠。

Abstract

To compare the diagnostic accuracy of CBCT images acquired with different imaging protocols for detecting tooth ankylosis. Thirty extracted permanent teeth (20 single-rooted, 10 three-rooted) were prepared; ankylosis was simulated in 20 by selectively removing Teflon from roots previously coated to mimic the periodontal ligament. Samples were embedded in stone plaster and imaged using 4 protocols on 2 CBCT units. CBCT images were primarily evaluated by a blinded radiologist (present/absent). Micro-CT was performed on 20% of specimens to verify the model. Agreement and accuracy metrics (Fleiss/Cohen κ, sensitivity, specificity, PPV, NPV) were calculated. Protocol 2 (0.25 mm voxel) showed the most favorable performance (κ = 0.113; sensitivity 71.4%; PPV 52.6%; NPV 60%). Protocol 3 (0.35 mm voxel) performed worst (κ = -0.104; sensitivity 53.8%; PPV 43.8%; NPV 45.5%). Except for Protocol 3, sensitivity was high (≥71.4%) while specificity remained low (35.7%-42.9%). The study has its own limits. Different imaging protocols using in clinical practice to detect ankylosis can be investigated as well to provide different approaches assessing ankylosis. CBCT demonstrated high sensitivity but low specificity for ankylosis detection, indicating a propensity for false positives. Smaller voxel sizes (0.25-0.30 mm) improved detection, whereas 0.35 mm was least reliable.

如何引用

AMA

Şelale Özel, Taha Emre Köse, Samed Şatır. Evaluation of imaging protocols for detecting tooth ankylosis using different CBCT devices: an in vitro study.. European journal of orthodontics. 2026; doi:10.1093/ejo/cjag043.

APA

Şelale Özel, Taha Emre Köse, Samed Şatır (2026). Evaluation of imaging protocols for detecting tooth ankylosis using different CBCT devices: an in vitro study.. European journal of orthodontics. https://doi.org/10.1093/ejo/cjag043

GB/T 7714

Şelale Özel, Taha Emre Köse, Samed Şatır. Evaluation of imaging protocols for detecting tooth ankylosis using different CBCT devices: an in vitro study.[J]. European journal of orthodontics, 2026 doi:10.1093/ejo/cjag043.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI