摘要(中文译文)

接触海绵法(CSM)和Karsten管等非破坏性技术已被开发用于现场测量中评估建筑材料的水吸收性能。相比之下,实验室研究通常依赖于对厘米级试样进行的毛细上升试验(CR),该试验施加一维水流。尽管这些方法所得结果在定性上具有可比性,但仍缺乏稳健的定量相关性。此前已有研究提出一种解析表达式,用于根据非破坏性技术的测量结果估算吸水性,其假设水渗透深度等于水在材料表面的横向扩散范围。在本研究中,我们通过将能够直接可视化水渗透的中子射线照相术与基于重量测量的常规毛细上升试验相结合,研究了接触海绵法所诱发的水吸收过程。研究了孔隙率范围为10%至30%的砂岩和石灰岩。中子成像揭示,渗透深度与横向扩散相等这一标准假设并不成立。这些观察结果被用于提出一种改进的解析表达式,该表达式考虑了非破坏性方法所诱发的三维水流。这显著改善了由CSM和CR试验获得的吸水性值之间的定量一致性。这一修订后的解析框架促成了对CSM现场测试方案的调整,以确保可靠的吸水性评估。在线版本包含补充材料,可访问10.1617/s11527-026-03118-0获取。

Abstract

Non-destructive techniques such as the contact sponge method (CSM) and the Karsten tube have been developed to assess the water absorption properties of building materials during field measurements. In contrast, laboratory investigations typically rely on capillary rise tests (CR) on centimetric specimens imposing a one-dimensional water flow. Although the results obtained from these methods are qualitatively comparable, a robust quantitative correlation is still lacking. An analytical expression has previously been proposed to estimate the sorptivity from measurements with non-destructive techniques, based on the assumption that the water penetration depth equals the lateral spreading of water on the material surface. In this study, we investigate the water absorption processes induced by the contact sponge method, by combining neutron radiography, which allows direct visualization of water penetration, with conventional capillary rise tests based on gravimetric measurements. Sandstones and limestones with porosities ranging from 10% to 30% were examined. Neutron imaging reveals that the standard assumption of equal penetration depth and lateral spreading is not valid. These observations were used to propose an improved analytical expression that accounts for the three-dimensional water flow induced by the non-destructive method. This significantly improves the quantitative agreement between sorptivity values obtained from CSM and CR tests. This revised analytical framework results in an adaptation of the CSM field-testing protocol to ensure reliable sorptivity assessment. The online version contains supplementary material available at 10.1617/s11527-026-03118-0.

如何引用

AMA

H Derluyn, J Desarnaud, D Vandevoorde, J Dewanckele, M N Boone, S Peetermans, et al. Quantifying sorptivity using the contact sponge method: an improved calculation method validated by classical capillary rise experiments and neutron radiography.. Materials and structures. 2026; doi:10.1617/s11527-026-03118-0.

APA

H Derluyn, J Desarnaud, D Vandevoorde, J Dewanckele, M N Boone, S Peetermans, et al (2026). Quantifying sorptivity using the contact sponge method: an improved calculation method validated by classical capillary rise experiments and neutron radiography.. Materials and structures. https://doi.org/10.1617/s11527-026-03118-0

GB/T 7714

H Derluyn, J Desarnaud, D Vandevoorde, J Dewanckele, M N Boone, S Peetermans, et al. Quantifying sorptivity using the contact sponge method: an improved calculation method validated by classical capillary rise experiments and neutron radiography.[J]. Materials and structures, 2026 doi:10.1617/s11527-026-03118-0.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI