抗磷脂抗体综合征和系统性红斑狼疮患者凝血酶原时间和INR测定的远程实验室测试的分析和临床验证
Analytical and Clinical Validation of a Remote Laboratory Test for Prothrombin Time and INR Determination in Patients with Antiphospholipid Antibody Syndrome and Systemic Lupus Erythematosus.
Analytical and Clinical Validation of a Remote Laboratory Test for Prothrombin Time and INR Determination in Patients with Antiphospholipid Antibody Syndrome and Systemic Lupus Erythematosus.
抗磷脂综合征(APS)是一种与抗磷脂抗体相关的自身免疫性疾病,可导致凝血失衡、血栓形成和产科并发症。它可作为原发性疾病发生,也可与系统性红斑狼疮(SLE)相关。APS患者通常需要长期抗凝治疗,并通过以国际标准化比值(INR)表示的凝血酶原时间(PT)进行监测。远程实验室检测(RLT)设备可能通过提供更快速、更便捷的结果来改善监测;然而,其在APS患者中的准确性仍不确定。本研究旨在验证一种快速便携式设备(bSens.INR)用于接受华法林治疗的APS和SLE患者PT/INR测量的效果,并与无这些疾病的对照组进行比较。依据既定指南评估了其准确性、重复性以及与标准实验室方法的一致性。使用bSens.INR共获得40次PT/INR测量结果,使用标准方法获得20次。总体一致性为77.5%,APS/SLE患者的一致性较低(60%),而对照组为95%。获批结果显示100%重复性。两种方法之间观察到强正相关(Spearman = 0.80,< 0.0001),而Bland-Altman分析显示偏差为0.26个INR单位。抗磷脂抗体的存在似乎会干扰bSens.INR获得的PT/INR测量结果,降低APS和SLE患者的准确性。尽管该设备表现出有前景的性能,但在自身免疫人群中使用时应谨慎,这进一步印证了此前关于RLT在这些疾病中局限性的研究结果。
Antiphospholipid syndrome (APS) is an autoimmune disorder associated with antiphospholipid antibodies, leading to coagulation imbalance, thrombosis, and obstetric complications. It may occur as a primary condition or in association with systemic lupus erythematosus (SLE). Patients with APS often require long-term anticoagulation therapy, monitored by prothrombin time (PT) expressed as international normalized ratio (INR). Remote laboratory testing (RLT) devices may improve monitoring by providing faster and more convenient results; however, their accuracy in APS patients remains uncertain. This study aimed to validate a rapid and portable device (bSens.INR) for PT/INR measurement in patients with APS and SLE receiving warfarin, compared to a control group without these conditions. Accuracy, repeatability, and agreement with the standard laboratory method were evaluated according to established guidelines. A total of 40 PT/INR measurements were obtained using the bSens.INR and 20 using the standard method. Overall concordance was 77.5%, with lower agreement in APS/SLE patients (60%) compared to controls (95%). Approved results showed 100% repeatability. A strong positive correlation was observed between methods (Spearman = 0.80, < 0.0001), while Bland-Altman analysis indicated a bias of 0.26 INR units. The presence of antiphospholipid antibodies appears to interfere with PT/INR measurements obtained by the bSens.INR, reducing accuracy in APS and SLE patients. Although the device shows promising performance, its use in autoimmune populations should be approached with caution, reinforcing previous findings on the limitations of RLT in these conditions.
Gabriela Victória de Mello Jantzch, Rodrigo Ritzel Bernasconi, Milleny Germann Souza, Duane da Silva Moraes, Bruna Ferri Serafini, Leonardo Peterson Dos Santos, et al. Analytical and Clinical Validation of a Remote Laboratory Test for Prothrombin Time and INR Determination in Patients with Antiphospholipid Antibody Syndrome and Systemic Lupus Erythematosus.. ACS omega. 2026; doi:10.1021/acsomega.6c02189.
Gabriela Victória de Mello Jantzch, Rodrigo Ritzel Bernasconi, Milleny Germann Souza, Duane da Silva Moraes, Bruna Ferri Serafini, Leonardo Peterson Dos Santos, et al (2026). Analytical and Clinical Validation of a Remote Laboratory Test for Prothrombin Time and INR Determination in Patients with Antiphospholipid Antibody Syndrome and Systemic Lupus Erythematosus.. ACS omega. https://doi.org/10.1021/acsomega.6c02189
Gabriela Victória de Mello Jantzch, Rodrigo Ritzel Bernasconi, Milleny Germann Souza, Duane da Silva Moraes, Bruna Ferri Serafini, Leonardo Peterson Dos Santos, et al. Analytical and Clinical Validation of a Remote Laboratory Test for Prothrombin Time and INR Determination in Patients with Antiphospholipid Antibody Syndrome and Systemic Lupus Erythematosus.[J]. ACS omega, 2026 doi:10.1021/acsomega.6c02189.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出