多枚小直径扇形与平行髓芯减压治疗早期股骨头坏死的生物力学对比分析

Biomechanical comparative analysis of multiple small diameter fan-shaped and parallel core decompression for early osteonecrosis of the femoral head.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

多枚小直径扇形与平行髓芯减压是用于治疗早期股骨头坏死的手术方式。然而,从生物力学角度来看,哪种方法更为合适尚不清楚。因此,我们旨在利用有限元分析来评估两种钻孔方式不同分布参数的力学稳定性。共建立了十个有限元模型,包括基于扇形和平行髓芯减压的不同钻孔数量(三孔、四孔、五孔、七孔和九孔)。通过计算股骨近端的应力和应变来评估生物力学稳定性。结果表明,在两组中,整个结构、大转子外侧壁和骨隧道中的最大等效应力均随着钻孔数量的增加而增大,顺序为:三孔<四孔<五孔<七孔<九孔。在相同孔数下,与平行髓芯减压相比,扇形髓芯减压在大转子外侧壁、皮质骨隧道、松质骨隧道及骨坏死区骨隧道中具有更高的最大等效应力,其中松质骨隧道的增幅显著(21.18%~585.71%)。此外,扇形钻孔表现出更高的平均应力和局部应变,尤其是在松质骨隧道中,而平行钻孔在大多数区域维持了较低的应力和应变水平。从生物力学角度来看,对于早期股骨头坏死,多枚小直径平行髓芯减压优于扇形减压,能够提供更好的稳定性并减少股骨近端的应力集中。

Abstract

Multiple small diameter fan-shaped and parallel core decompression are the surgical procedure used to treat the early osteonecrosis of the femoral head. However, It is not known which method is more appropriate from biomechanical perspective. Therefore, we aimed to analyze the mechanical stability of different distribution parameters of the two drilling methods using finite element analysis. Ten finite element models were established, including different drilling number (three-hole, four-hole, five-hole, seven-hole and nine-hole) based on fan-shaped and parallel core decompression. The stress and strain of the proximal femur was calculated to evaluate the biomechanical stability. Results showed that maximum equivalent stress in the entire structure, greater trochanter's lateral wall, and bone tunnels increased with more drill holes in both groups, following the order: three-hole < four-hole < five-hole < seven-hole < nine-hole. At the same hole count, fan-shaped core decompression had higher maximum equivalent stress in the greater trochanter's lateral wall, cortical bone tunnel, cancellous bone tunnel, and bone tunnel in the osteonecrosis area compared to parallel core decompression, with notable percentage increases in the cancellous bone tunnel (21.18%-585.71%). Additionally, fan-shaped drilling exhibited higher average stress and local strain, especially in the cancellous bone tunnel, whereas parallel drilling maintained lower stress and strain levels across most regions. From a biomechanical perspective, multiple small-diameter parallel core decompression is superior to fan-shaped decompression, offering better stability and reduced stress concentration in the proximal femur for early femoral head osteonecrosis.

如何引用

AMA

Daizhu Yuan, Jianya Qiu, Zhonghui Yao, Cheng Wu, Jiayi Luo, Chuan Ye. Biomechanical comparative analysis of multiple small diameter fan-shaped and parallel core decompression for early osteonecrosis of the femoral head.. Frontiers in bioengineering and biotechnology. 2026; doi:10.3389/fbioe.2026.1773122.

APA

Daizhu Yuan, Jianya Qiu, Zhonghui Yao, Cheng Wu, Jiayi Luo, Chuan Ye (2026). Biomechanical comparative analysis of multiple small diameter fan-shaped and parallel core decompression for early osteonecrosis of the femoral head.. Frontiers in bioengineering and biotechnology. https://doi.org/10.3389/fbioe.2026.1773122

GB/T 7714

Daizhu Yuan, Jianya Qiu, Zhonghui Yao, Cheng Wu, Jiayi Luo, Chuan Ye. Biomechanical comparative analysis of multiple small diameter fan-shaped and parallel core decompression for early osteonecrosis of the femoral head.[J]. Frontiers in bioengineering and biotechnology, 2026 doi:10.3389/fbioe.2026.1773122.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Frontiers in bioengineering and biotechnology 的其他文献