通过不确定性评估提高基于MRI的自动分割的置信度

Improving confidence in MRI-based auto-segmentation via uncertainty assessment.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

感兴趣器官(OOIs,也常称为危及器官,OARs)的准确勾画对于安全放疗至关重要。尽管基于卷积神经网络的深度学习分割已实现较高的几何精度,但其在解剖学模糊区域中过度自信、未经校准的预测阻碍了临床转化。不确定性量化和模型校准是安全临床工作流程的前提条件。本研究将标准nnU-Netv2与其残差编码变体(ResEncM)进行比较,假设ResEncM将表现出更优的可靠性和校准性能,同时保持相当的几何精度。患者/材料与方法:使用70例脑癌患者的T1加权对比增强MRI扫描(55例用于训练/验证,15例用于测试)。根据丹麦神经肿瘤学组指南勾画脑干、海马、视交叉、视神经、视束和垂体的金标准轮廓。两种架构均采用五折交叉验证进行训练,预处理完全相同。使用互信息量化认知不确定性,并在参考轮廓周围10 mm各向同性边缘内计算期望校准误差(ECE)。两种模型均达到较高的几何精度(脑干Dice相似系数[DSC] > 0.93,海马DSC > 0.81)。大型结构未发现显著的几何差异。ResEncM在垂体(p = 0.003)和视交叉(p = 0.018)方面显示出显著较低的DSC。然而,ResEncM在所有结构上均表现出显著更低的认知不确定性和集成方差(p < 0.05),并显著降低了视交叉、视束和垂体的ECE。将深度残差编码器整合到标准U-Net框架中,可显著提高自动化脑部OOI轮廓的可靠性和校准性能,同时保持较强的几何性能。ResEncM架构通过可靠地标记高不确定性体素,为临床放疗提供了更值得信赖的工具,支持置信度感知的临床工作流程。

Abstract

Accurate delineation of organs of interest (OOIs, also commonly referred to as organs at risk, OARs) is crucial for safe radiotherapy. While deep learning-based segmentation using convolutional neural networks has achieved high geometric accuracy, clinical translation is hindered by overconfident, uncalibrated predictions in anatomically ambiguous regions. Uncertainty quantification and model calibration are prerequisites for safe clinical workflows. This study compared the standard nnU-Netv2 against its residual-encoding variant (ResEncM), hypothesizing that ResEncM would demonstrate superior reliability and calibration while maintaining comparable geometric accuracy. Patient/material and methods: T1-weighted contrast-enhanced MRI scans from 70 brain cancer patients were used (55 training/validation, 15 testing). Ground-truth contours for brainstem, hippocampi, chiasm, optic nerves, optic tracts, and pituitary were delineated per Danish Neuro Oncology Group guidelines. Both architectures were trained using five-fold cross-validation with identical preprocessing. Epistemic uncertainty was quantified using mutual information, and Expected Calibration Error (ECE) was computed within a 10-mm isotropic margin around reference contours. Both models achieved high geometric accuracy (brainstem dice similarity coefficient [DSC] > 0.93, hippocampi DSC > 0.81). No significant geometric differences were found for large structures. ResEncM showed significantly lower DSC for the pituitary (p = 0.003) and chiasm (p = 0.018). However, ResEncM demonstrated significantly lower epistemic uncertainty and ensemble variance across all structures (p < 0.05), and significantly reduced ECE for the optic chiasm, optic tracts, and pituitary. Integrating a deep residual encoder into the standard U-Net framework significantly improves reliability and calibration of automated brain OOI contours while maintaining strong geometric performance. The ResEncM architecture provides a more trustworthy tool for clinical radiotherapy by reliably flagging high-uncertainty voxels, supporting confidence-aware clinical workflows.

如何引用

AMA

Jesper Folsted Kallehauge, Jintao Ren, Yasmin Lassen-Ramshad. Improving confidence in MRI-based auto-segmentation via uncertainty assessment.. Acta oncologica (Stockholm, Sweden). 2026; doi:10.2340/1651-226X.2026.45685.

APA

Jesper Folsted Kallehauge, Jintao Ren, Yasmin Lassen-Ramshad (2026). Improving confidence in MRI-based auto-segmentation via uncertainty assessment.. Acta oncologica (Stockholm, Sweden). https://doi.org/10.2340/1651-226X.2026.45685

GB/T 7714

Jesper Folsted Kallehauge, Jintao Ren, Yasmin Lassen-Ramshad. Improving confidence in MRI-based auto-segmentation via uncertainty assessment.[J]. Acta oncologica (Stockholm, Sweden), 2026 doi:10.2340/1651-226X.2026.45685.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI

Acta oncologica (Stockholm, Sweden) 的其他文献