完全引导与部分引导下颧骨种植体放置的准确性
Accuracy of Zygomatic Implant Placement Using Completely Versus Partially Guided.
Accuracy of Zygomatic Implant Placement Using Completely Versus Partially Guided.
颧种植体植入是一项具有挑战性的外科手术,因为种植体植入时的可及性和可视性均有限。本研究旨在比较完全限制性与部分限制性计算机生成三维手术导板在萎缩性上颌骨患者颧种植体植入中的精度。本前瞻性随机对照研究纳入适用于颧种植体(ZI)植入的萎缩性上颌后牙区患者。参与者被随机分配至两组之一。I组使用完全限制性三维计算机引导手术模板进行ZI植入,II组使用部分限制性三维计算机引导手术模板进行ZI植入。主要结局变量为种植体植入精度,通过测量种植体冠部和根尖点的线性偏差以及角度偏差进行评估。次要结局为手术时间。本研究评估了6例患者(平均年龄:56.9 ± 7.57岁)中的12枚颧种植体(每组6枚)。两组之间的基线人口学特征和临床特征均衡良好,年龄和性别分布相当。除II组在正中矢状面上的根尖偏差显著较大外(p = 0.015),两组之间的线性偏差或角度偏差均无统计学显著差异。II组的平均手术时间(21.17 ± 2.14分钟)显著短于I组(27 ± 2.37分钟)(p = 0.01)。未发生脱落或术后并发症(如感染、种植体周围炎或鼻窦相关问题)。在本研究样本量的局限性范围内,部分限制性手术导板可为颧种植体植入提供一种成功且创伤较小的治疗方式,因为它在总体精度相当的情况下显著缩短了手术时间。然而,完全限制性导板在关键的种植体根尖位置表现出更优越的控制力。ClinicalTrials.org(NCT06227351)2024-02-05。
Zygomatic implant placement is a challenging surgical procedure, as the implants are inserted with limited accessibility and visibility. The aim of this study was to compare the accuracy of completely limiting versus partially limiting computer-generated 3D surgical guides for zygomatic implant placement in patients with atrophic maxillae. This prospective randomized controlled study included participants with atrophic posterior maxilla indicated for zygomatic implant (ZI) placement. The participants were randomly allocated to one of two groups. Group I received ZI using completely limiting 3D computer-guided surgical templates, while Group II underwent ZI placement using partially limiting 3D computer-guided surgical templates. The primary outcome variable was the accuracy of implant placement, which was assessed by measuring linear deviations at the implant coronal and apical points, as well as angular deviations. The secondary outcome was the duration of the operative time. This study evaluated 12 zygomatic implants (6 per group) in 6 patients (mean age: 56.9 ± 7.57 years). Baseline demographics and clinical features were well-balanced between groups, with comparable age and sex distributions. There were no statistically significant differences in linear or angular deviations between the groups, except for a statistically significant greater apical deviation in the midsagittal plane for Group II (p = 0.015). Group II had a significantly shorter mean operative time (21.17 ± 2.14 min) than Group I (27 ± 2.37 min) (p = 0.01). No dropouts or postoperative complications (e.g., infection, peri-implantitis, or sinus-related issues) have occurred. Within the limitations of the sample size of this study, the partially limiting surgical guide could provide a successful and less invasive treatment modality for zygomatic implant placement, as it significantly reduces the surgical time with comparable overall accuracy. However, the completely limiting guide demonstrates superior control at the critical apical implant position. ClinicalTrials.org (NCT06227351) 2024-02-05.
Mohamed Kamal Ghallab, Alshaimaa Ahmed Shabaan, Haytham Al-Mahalawy, Moustafa Taha. Accuracy of Zygomatic Implant Placement Using Completely Versus Partially Guided.. BMC oral health. 2026; doi:10.1186/s12903-026-08436-x.
Mohamed Kamal Ghallab, Alshaimaa Ahmed Shabaan, Haytham Al-Mahalawy, Moustafa Taha (2026). Accuracy of Zygomatic Implant Placement Using Completely Versus Partially Guided.. BMC oral health. https://doi.org/10.1186/s12903-026-08436-x
Mohamed Kamal Ghallab, Alshaimaa Ahmed Shabaan, Haytham Al-Mahalawy, Moustafa Taha. Accuracy of Zygomatic Implant Placement Using Completely Versus Partially Guided.[J]. BMC oral health, 2026 doi:10.1186/s12903-026-08436-x.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出