干粉吸入器制剂中活性药物成分粒径的测定
Determination of Particle Size of Active Pharmaceutical Ingredients in Dry Powder Inhaler Formulations.
Determination of Particle Size of Active Pharmaceutical Ingredients in Dry Powder Inhaler Formulations.
准确测定干粉吸入剂(DPI)制剂中活性药物成分(API)的粒径对于确保有效的肺部递送至关重要,但由于API含量低且粒径为微米级,该测定在分析上仍具有挑战性。本研究采用扫描电子显微镜(SEM)联用能量色散X射线微分析(EDX),在符合法规约束的前提下,直接识别并计算多种不同市售DPI产品中的API粒径。该方法利用每种API固有的独特元素标记,无需事先对样品进行修饰或提取API,即可实现与辅料的可靠区分。采用大面积SEM-EDX mapping定位API颗粒,随后进行高倍成像和验证性点微分析。使用图像分析软件对每种制剂中至少50个API颗粒进行手动粒径测量,并根据等效球径计算粒径分布参数。该方法已成功应用于思力华(Spiriva)、Anoro Ellipta和Relvar Ellipta吸入粉雾剂,揭示了具有不同形态特征的微粉化API,并验证了该方法在不同产品间的系统性应用。与纯API激光衍射测量结果的交叉验证表明两者具有统计学等效性,证实了所提出方法在DPI制剂粒径评估中的稳健性和分析实用性。
Accurate determination of active pharmaceutical ingredient (API) particle size within dry powder inhaler (DPI) formulations is essential for ensuring effective pulmonary delivery but remains analytically challenging due to low API content and micronized particle size. In this study, scanning electron microscopy (SEM) coupled with energy-dispersive X-ray microanalysis (EDX) was used to directly identify and calculate the API particle size within several different commercial DPI products fit for purpose under regulatory constraints. The method exploits unique elemental markers inherent to each API, enabling reliable discrimination from excipients without prior sample modification or API extraction. Large-area SEM-EDX mapping was used to localize API particles, followed by high-magnification imaging and confirmatory spot microanalysis. Particle sizes were manually measured for at least 50 API particles per formulation using image analysis software, and particle size distribution parameters were calculated from equivalent spherical diameters. The methodology was successfully applied to Spiriva, Anoro Ellipta, and Relvar Ellipta inhalation powders, revealing micronized APIs with distinct morphological features and verifying systematic application across products. Cross-validation against laser diffraction measurements of pure APIs demonstrated statistical equivalence, confirming the robustness and analytical utility of the proposed method for particle size assessment in DPI formulations.
Stefani Fertaki, Malvina Orkoula, Christos Kontoyannis. Determination of Particle Size of Active Pharmaceutical Ingredients in Dry Powder Inhaler Formulations.. Pharmaceuticals (Basel, Switzerland). 2026; doi:10.3390/ph19040543.
Stefani Fertaki, Malvina Orkoula, Christos Kontoyannis (2026). Determination of Particle Size of Active Pharmaceutical Ingredients in Dry Powder Inhaler Formulations.. Pharmaceuticals (Basel, Switzerland). https://doi.org/10.3390/ph19040543
Stefani Fertaki, Malvina Orkoula, Christos Kontoyannis. Determination of Particle Size of Active Pharmaceutical Ingredients in Dry Powder Inhaler Formulations.[J]. Pharmaceuticals (Basel, Switzerland), 2026 doi:10.3390/ph19040543.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出