可拉伸介孔电极作为微创手术设备的多功能平台

Stretchable mesoporous electrodes as a versatile platform for minimally invasive surgical devices.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

微创手术(MIS)是治疗多种心脏和神经疾病的重要方法,例如清除堵塞的动脉、起搏不规则心跳、监测颅内压以及引流脑内多余的脑脊液。近年来软电子学的研究进展表明,集成电极在提升微创手术性能方面具有潜力,能够实现生物电位测量、电刺激和生物阻抗传感。这些功能的加入拓展了微创手术的应用前景,使其能够实施靶向心脏干预,或通过术中脑活动监测进一步降低风险。现有的传感器集成导管仍存在若干缺陷,例如导管外径显著增大、电极性能不一致、制造可扩展性有限以及缺乏主动转向能力。我们在此报道了采用介孔金作为功能层开发的柔性电极,其具有增强的表面阻抗特性可用于记录,高电荷注入容量可用于刺激,以及机械柔顺性可集成到各种不同直径的微创手术工具中。将该电极集成到由嵌入式微流控通道和微管驱动的软体机器人导管中,展示了一个具有可操控性的系统,在各种弯曲条件下均具有电学和机械稳定性,同时具有适合微创手术的低系统外径。通过一系列实验,我们展示了该系统在多种生物医学应用中的潜力,包括场电位测量、生物阻抗传感和心脏起搏,这些应用能够充分利用微创手术的能力。

Abstract

Minimally invasive surgery (MIS) is a vital procedure for the treatment of several cardiac and neural diseases, such as clearing clogged arteries, pacing irregular heartbeats, monitoring intracranial pressure, and draining excess cerebrospinal fluid from the brain. Recent research advances in soft electronics demonstrate the potential of integrated electrodes in enhancing MIS performance, enabling biopotential measurement, electrical stimulation, and bioimpedance sensing. The addition of these modalities expands the potential of MIS to deliver targeted cardiac interventions or further minimize risks through brain activity monitoring during the procedure. Existing sensor-integrated catheters still exhibit several drawbacks, such as a sizable increase in catheter profile, inconsistent electrode performance, limited fabrication scalability, and a lack of active steering capability. We report here the development of flexible electrodes using mesoporous gold as a functional layer with enhanced surface impedance characteristics for recording, high charge injection capacity for stimulation, and mechanical compliance for integration into a wide range of MIS tools with varied diameters. Integrating the electrode into a soft robotic catheter driven by an embedded microfluidic channel and microtubing demonstrates a manoeuvrable system with electrical and mechanical stability under various bending conditions, together with a low system profile suitable for a minimally invasive procedure. Through a set of and experiments, we demonstrate the potential of our system for various biomedical applications, including field potential measurement, bioimpedance sensing, and cardiac pacing, that can leverage the capability of MIS procedures.

如何引用

AMA

Michael Abraham Listyawan, Chi Cong Nguyen, Tran Bach Dang, Nhat Mihn Doan, Quang Anh Nguyen, Yulin Qiu, et al. Stretchable mesoporous electrodes as a versatile platform for minimally invasive surgical devices.. Lab on a chip. 2026; doi:10.1039/d6lc00110f.

APA

Michael Abraham Listyawan, Chi Cong Nguyen, Tran Bach Dang, Nhat Mihn Doan, Quang Anh Nguyen, Yulin Qiu, et al (2026). Stretchable mesoporous electrodes as a versatile platform for minimally invasive surgical devices.. Lab on a chip. https://doi.org/10.1039/d6lc00110f

GB/T 7714

Michael Abraham Listyawan, Chi Cong Nguyen, Tran Bach Dang, Nhat Mihn Doan, Quang Anh Nguyen, Yulin Qiu, et al. Stretchable mesoporous electrodes as a versatile platform for minimally invasive surgical devices.[J]. Lab on a chip, 2026 doi:10.1039/d6lc00110f.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI