用于微波肝脏治疗再规划的数字化双胞胎
A digital twin for microwave liver treatment replanning.
A digital twin for microwave liver treatment replanning.
微波消融(MWA)建模与仿真在肝脏肿瘤的局部区域治疗中具有巨大潜力。然而,按照计划的方向/位置精确放置天线在技术上具有挑战性。在发生错位的情况下,维持原计划可能导致消融不完全,而重新放置天线则可能引起肿瘤种植。在本研究中,我们提出了(i)MWA的数字孪生,可模拟消融结果,以及(ii)一种优化器,可在不重新插入天线的情况下建议对MWA参数的修正,同时确保肿瘤完全消融。采用有限元方法求解控制MWA的微波传播与传热耦合方程,其个性化介电特性和热特性由术前CT和MRI图像确定。随后,我们提出了一种优化算法,能够调整功率输入、消融持续时间和天线位置,以校正天线错位。该模拟器和优化器通过体内猪实验数据进行了评估。在血管化程度不同的肝脏区域进行了三次消融。尽管天线附近存在大血管,仿真仍准确预测了消融区域,Dice评分分别为0.82、0.81和0.79。在重新规划场景中,我们的优化器预测了新的参数集,其Dice评分分别为0.83、0.83、0.80,相较于初始消融结果,平均分别提高了20.3%、40.7%和48.1%。本文首次针对热消融治疗的术中重新规划进行了研究。研究结果表明,通过优化特定消融参数,无需重新插入天线即可实现最佳消融结果。
Microwave ablation (MWA) modeling and simulation bear great potential for locoregional treatment of liver tumors. However, accurately positioning the antenna according to a planned orientation/location is technically challenging. In cases of misplacement, maintaining the original plan may cause incomplete ablation, while repositioning the antenna may induce tumor seeding. In this work, we propose (i) a digital twin of MWA that simulates ablation outcomes and (ii) an optimizer that suggests corrections to MWA parameters without antenna reinsertion, while ensuring complete tumor ablations. A finite element scheme was used to solve the coupled microwave propagation and heat transfer equations governing MWA, with personalized dielectric and thermal properties determined from preoperative CT and MRI images. We then proposed an optimization algorithm able to adjust power input, ablation duration, and antenna position to correct for antenna misplacement. The simulator and optimizer were evaluated against in vivo swine experimental data. Three ablations were performed in liver regions with varying vascularization. The simulations accurately predicted the ablation zones despite the presence of large vessels near the antenna, achieving Dice scores of 0.82, 0.81, and 0.79. In the case of replanning scenarios, our optimizer predicted new parameter sets that led to Dice scores of 0.83, 0.83, 0.80, a corresponding improvement of 20.3%, 40.7%, and 48.1% in average over the initial ablation result. This paper is the first to address intra-operative replanning of thermal ablation therapy. It demonstrates that optimal ablation results can be achieved without requiring antenna reinsertion by optimizing specific ablation parameters.
Ilias Nahmed, Francesco Dettori, Juan Verde, Michel Duprez, Pablo Alvarez, Stéphane Cotin. A digital twin for microwave liver treatment replanning.. International journal of computer assisted radiology and surgery. 2026; doi:10.1007/s11548-026-03641-z.
Ilias Nahmed, Francesco Dettori, Juan Verde, Michel Duprez, Pablo Alvarez, Stéphane Cotin (2026). A digital twin for microwave liver treatment replanning.. International journal of computer assisted radiology and surgery. https://doi.org/10.1007/s11548-026-03641-z
Ilias Nahmed, Francesco Dettori, Juan Verde, Michel Duprez, Pablo Alvarez, Stéphane Cotin. A digital twin for microwave liver treatment replanning.[J]. International journal of computer assisted radiology and surgery, 2026 doi:10.1007/s11548-026-03641-z.
翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出