新型犬14天心电图贴片监测仪的初步评估

Preliminary Assessment of a Novel 14-Day Electrocardiographic Adhesive Patch Monitor in Dogs.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

心律失常往往是短暂性的,使用常规心电图(ECG)技术可能无法检测到。黏附式贴片监测仪(APM)是一种单导联、轻便、可连续动态心电监测长达14天的设备。本研究旨在前瞻性评估其在四只拳师犬中的可用性,这些犬被认为健康或患有致心律失常性右心室心肌病。通过将APM放置在动物胸部左侧第五肋间、肋软骨连接处稍背侧,并使其垂直或平行于心脏长轴方向,可获得最佳记录。在三只犬中,APM保持了14天的粘贴状态。一只犬在59小时后移除了APM。所有犬均记录到皮肤刺激,并在移除APM后自行消退。可分析时间占总佩戴时间的93%以上,记录在静息状态下提供了明确的节律诊断。行走、奔跑或玩耍会引起间歇性运动伪差,可能影响心电图判读。APM结果与24小时Holter监测所获得的结果相当。在拳师犬中使用APM进行延长连续心电监测是可行的,并能提供可判读的记录。

Abstract

Cardiac arrhythmias often are transient and might not be detected using conventional electrocardiographic (ECG) techniques. The adhesive patch monitor (APM) is a single-lead, lightweight, up to 14-day continuous ambulatory ECG monitor. This study aimed to prospectively assess its usability in four boxer dogs considered either to be healthy or to have arrhythmogenic right ventricular cardiomyopathy. Optimal recording was obtained by placing the APM on the left side of the animal's thorax, at the fifth intercostal space, slightly dorsal to the costochondral junction, and oriented either vertically or parallel to the long axis of the heart. In three dogs, the APM remained attached for 14 days. One dog removed the APM after 59 hr. Skin irritation was documented in all dogs and resolved spontaneously after removal of the APM. The analyzable time was >93% of the total wear time and recordings provided an unambiguous rhythm diagnosis at rest. Walking, running, or playing caused intermittent motion artifact that could impair ECG interpretation. APM results were comparable to those obtained with 24-hr Holter monitoring. Extended continuous ECG monitoring with the APM is feasible in boxer dogs and provides interpretable recordings.

如何引用

AMA

Jonathan Lichtenberger, Kathryn M Meurs, Etienne Côté. Preliminary Assessment of a Novel 14-Day Electrocardiographic Adhesive Patch Monitor in Dogs.. Journal of the American Animal Hospital Association. 2018; doi:10.5326/JAAHA-MS-6626.

APA

Jonathan Lichtenberger, Kathryn M Meurs, Etienne Côté (2018). Preliminary Assessment of a Novel 14-Day Electrocardiographic Adhesive Patch Monitor in Dogs.. Journal of the American Animal Hospital Association. https://doi.org/10.5326/JAAHA-MS-6626

GB/T 7714

Jonathan Lichtenberger, Kathryn M Meurs, Etienne Côté. Preliminary Assessment of a Novel 14-Day Electrocardiographic Adhesive Patch Monitor in Dogs.[J]. Journal of the American Animal Hospital Association, 2018 doi:10.5326/JAAHA-MS-6626.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI