D-SPECT的性能评估:一种用于核素心脏学的新型SPECT系统

Performance evaluation of D-SPECT: a novel SPECT system for nuclear cardiology.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

D-SPECT(Spectrum Dynamics,以色列)是一种用于心脏灌注研究的新型SPECT系统。基于CZT探测器、以区域为中心的扫描方式、高灵敏度准直器和分辨率恢复技术,它相较于传统系统具有潜在优势。为评估其在能量分辨率、散射分数、灵敏度、计数率能力和分辨率方面的性能,对一台β版D-SPECT系统进行了一系列测量。同时也在传统SPECT系统(CS)上进行了相应测量以作比较。D-SPECT系统在140 keV处的能量分辨率为5.5%(CS:9.25%),散射分数为30%(CS:34%),平面灵敏度为398 s(-1) MBq(-1)每探头((99m)Tc,10 cm)(CS:72 s(-1) MBq(-1)),心脏区域的断层灵敏度在647-1107 s(-1) MBq(-1)范围内(CS:141 s(-1) MBq(-1))。计数率随活度增加呈线性上升,直至1.44 M s(-1)。固有分辨率等于像素尺寸,为2.46 mm(CS:3.8 mm)。使用标准临床滤波器重建后的平均分辨率为12.5 mm(CS:13.7 mm)。D-SPECT在空间分辨率相近的情况下,灵敏度优于传统系统。它还具有出色的能量分辨率和计数率特性,这在动态和双放射性核素研究中应能发挥作用。

Abstract

D-SPECT (Spectrum Dynamics, Israel) is a novel SPECT system for cardiac perfusion studies. Based on CZT detectors, region-centric scanning, high-sensitivity collimators and resolution recovery, it offers potential advantages over conventional systems. A series of measurements were made on a beta-version D-SPECT system in order to evaluate its performance in terms of energy resolution, scatter fraction, sensitivity, count rate capability and resolution. Corresponding measurements were also done on a conventional SPECT system (CS) for comparison. The energy resolution of the D-SPECT system at 140 keV was 5.5% (CS: 9.25%), the scatter fraction 30% (CS: 34%), the planar sensitivity 398 s(-1) MBq(-1) per head ((99m)Tc, 10 cm) (CS: 72 s(-1) MBq(-1)), and the tomographic sensitivity in the heart region was in the range 647-1107 s(-1) MBq(-1) (CS: 141 s(-1) MBq(-1)). The count rate increased linearly with increasing activity up to 1.44 M s(-1). The intrinsic resolution was equal to the pixel size, 2.46 mm (CS: 3.8 mm). The average reconstructed resolution using the standard clinical filter was 12.5 mm (CS: 13.7 mm). The D-SPECT has superior sensitivity to that of a conventional system with similar spatial resolution. It also has excellent energy resolution and count rate characteristics, which should prove useful in dynamic and dual radionuclide studies.

如何引用

AMA

Kjell Erlandsson, Krzysztof Kacperski, Dean van Gramberg, Brian F Hutton. Performance evaluation of D-SPECT: a novel SPECT system for nuclear cardiology.. Physics in medicine and biology. 2009; doi:10.1088/0031-9155/54/9/003.

APA

Kjell Erlandsson, Krzysztof Kacperski, Dean van Gramberg, Brian F Hutton (2009). Performance evaluation of D-SPECT: a novel SPECT system for nuclear cardiology.. Physics in medicine and biology. https://doi.org/10.1088/0031-9155/54/9/003

GB/T 7714

Kjell Erlandsson, Krzysztof Kacperski, Dean van Gramberg, Brian F Hutton. Performance evaluation of D-SPECT: a novel SPECT system for nuclear cardiology.[J]. Physics in medicine and biology, 2009 doi:10.1088/0031-9155/54/9/003.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI