桡骨头骨折合并肘关节脱位:浮动桡骨头假体治疗的结果

Fracture of the radial head with associated elbow dislocation: results of treatment using a floating radial head prosthesis.

获取 PDF 原文 在 PubMed增强版打开

摘要(中文译文)

评估采用浮动假体手术治疗的桡骨头骨折合并肘关节脱位患者的肘关节功能、并发症及问题。前瞻性临床研究。比利时列日Sart Tilman大学医院骨科。1994年1月至1996年9月,连续11例成年患者因急性桡骨头骨折合并肘关节脱位接受浮动假体治疗。所有患者均使用浮动桡骨头假体(Tornier SA,Saint-Ismier,法国)。该植入物由两部分组成:一个由高密度聚乙烯制成并包裹于钴铬合金杯中的桡骨头,其以半限制方式与骨水泥型髓内柄的球形末端相关节。植入物在伤后第一周内(范围2至7天)置入。3例还需对尺骨冠突进行内固定;1例还进行了尺骨鹰嘴骨折的钢板固定。通过体格检查、功能评分指数(Morrey等)和X线片对患者进行评估。评估参数为活动度、稳定性、疼痛和握力。对感染、假体失败或脱位等潜在并发症进行了调查。最短随访时间为两年(平均32个月,范围24至56个月)。4例患者结果评定为优,4例为良,2例为可,1例为差。无感染、假体失败或脱位病例。无患者需要假体翻修。在决定桡骨头骨折合并肘关节脱位的治疗时,维持解剖和生理关系的基本原则仍然适用。外侧骨性支撑的丧失将使肘关节严重不稳定。我们认为,浮动假体可能适用于Mason III型桡骨头骨折合并肘关节脱位,尤其是在存在相关失稳性骨折时。需要设计良好的对照随机研究来确定特定情况下的最佳治疗方案。

Abstract

To assess elbow function, complications, and problems of radial head fractures associated with elbow dislocation receiving surgical treatment with a floating prosthesis. Prospective clinical study. University Hospital, Orthopaedic Department, Sart Tilman, Liège, Belgium. Eleven consecutive adult patients were treated with a floating prosthesis for acute radial head fractures associated with elbow dislocation from January 1994 to September 1996. The floating radial head prosthesis (Tornier SA, Saint-Ismier, France) was used in all our patients. The implant is in two parts: a radial head made of high-density polyethylene enclosed in a cobalt-chrome cup, which articulates in a semiconstrained manner with the spherical end of a cemented intramedullary stem. The implants were inserted within the first week following the injury (range 2 to 7 days). Three cases also required internal fixation of the coronoid process of the ulna; in one case plate fixation of an olecranon fracture was also performed. Patients were assessed by physical examination, a functional rating index (Morrey et al.), and radiographs. The parameters evaluated were motion, stability, pain, and grip strength. Potential complications such as infection, prosthetic failure, or dislocation were investigated. The minimum follow-up time was two years (mean 32 months, range 24 to 56 months). Four patients were considered to have excellent results, four patients were considered to have good results, two patients had fair results, and one patient had a poor result. There were no cases of infection, prosthetic failure, or dislocation. No patient required prosthetic revision. The basic principle of maintaining anatomic and physiologic relationships applies when deciding on treatment for radial head fractures with associated elbow dislocation. The loss of lateral osseous support will render the elbow grossly unstable. We believe that a floating prosthesis may be indicated in Mason Type III radial head fractures associated with elbow dislocation, especially in the presence of associated destabilizing fractures. Well-controlled comparative randomized studies will be needed to delineate the optimal treatment for a given situation.

如何引用

AMA

N Popovic, P Gillet, A Rodriguez, R Lemaire. Fracture of the radial head with associated elbow dislocation: results of treatment using a floating radial head prosthesis.. Journal of orthopaedic trauma. doi:10.1097/00005131-200003000-00004.

APA

N Popovic, P Gillet, A Rodriguez, R Lemaire Fracture of the radial head with associated elbow dislocation: results of treatment using a floating radial head prosthesis.. Journal of orthopaedic trauma. https://doi.org/10.1097/00005131-200003000-00004

GB/T 7714

N Popovic, P Gillet, A Rodriguez, R Lemaire. Fracture of the radial head with associated elbow dislocation: results of treatment using a floating radial head prosthesis.[J]. Journal of orthopaedic trauma doi:10.1097/00005131-200003000-00004.

在 PubMed增强版 阅读全文

翻译全文 · AI 文献问答 · PDF 原文下载 · 引用导出

获取 PDF 原文 在 PubMed增强版打开 PubMed 原文 DOI